Microchip gel electrophoretic analysis of perchloric acid-soluble serum proteins in systemic inflammatory disorders

利用微芯片凝胶电泳分析系统性炎症疾病中高氯酸可溶性血清蛋白

阅读:1

Abstract

Perchloric acid (PCA) precipitation is a well-known method for the separation of heavily glycosylated proteins and for reducing the masking effect of major serum proteins. The aim of this study is to characterize PCA-soluble serum proteins in healthy individuals and in patients with systemic inflammatory diseases, such as Crohn's disease and sepsis. A PCA precipitation protocol was prepared and adapted to the analytical methods. After PCA treatment of the serum, the soluble proteins in the supernatant were analyzed by SDS-PAGE and by microchip gel electrophoresis (MGE). Characteristic changes of the electrophoretic patterns of the PCA-soluble fractions were observed. Four characteristic bands (at ∼11, ∼65, ∼85, and ∼120 kDa) with varying intensity were detected by MGE. The proportion of the ∼65, ∼85, and ∼120 kDa bands were significantly higher in systemic inflammatory conditions than in healthy individuals (p < 0.001), and characteristic patterns were observed in patients with acute inflammation. The marked differences in the acid-soluble protein patterns, which were observed in patients with ongoing systemic inflammation, might be a good indicator of inflammation. The MGE analysis is a fast screening and quantification method for the detection of characteristic changes among acid-soluble serum proteins.