Automated and Fully Validated High-Throughput LC-MS/MS Assay for Analyzing Multiple Drugs of Abuse in Oral Fluids Using Novel Features in Sample Preparation and Chromatographic Conditions

利用样品制备和色谱条件方面的创新,开发了一种自动化且完全验证的高通量液相色谱-串联质谱(LC-MS/MS)分析方法,用于分析口腔液中的多种滥用药物。

阅读:1

Abstract

Oral fluid sampling offers advantages over other biological matrices, mainly due to its noninvasive procedure avoiding privacy intrusion. The fully automated sample preparation procedure is based on salting-out assisted liquid-liquid extraction (SALLE) combined with high-efficiency LC-MS/MS methods for both screening and confirmation of 37 drugs and incorporates novel features enabling direct injection of acetonitrile extracts into an innovative chromatographic system. The methods' drug panel includes opioids, benzodiazepines, benzodiazepine-like drugs, cannabinoids, and stimulants. A full method validation was performed using OF/buffer from Greiner Bio-ONE International and Quantisal saliva collection devices. The validation included assessments of linearity, sensitivity, precision, accuracy, extraction recovery, matrix effects, process efficiency, stability, and carryover. All compounds demonstrated linearity across the concentration range 1-25 ng/mL, with R(2) ≥ 0.99. Both methods' limit of detection ranged between 0.001 and 0.03 ng/mL, and the limit of quantification ranged between 0.02 and 0.09 ng/mL. Precision was ≤ 14.8% for screening and ≤ 8.5% for the confirmation method. Accuracy was ± 13.6% for screening and ± 8.7% (except at 0.5 and 1 ng/mL, where it was ± 25.3% and ± 17.6%, respectively) for the confirmation method. Extraction recoveries ranged from 40.0% to 95.1%, except for hydromorphone (27.4%) and morphine (34.4%). Although matrix effects were observed for a large number of compounds to varying degrees, they were largely compensated for by the use of deuterium- and (13)C-labeled internal standards (IS). IS-corrected overall process efficiency ranged from 100.7% to 119.1% with precision (CV%) ≤ 10.8% for all compounds. Spiked calibrators and QC samples in OF were stable in autosampler for up to 72 h and in the freezer for 3 days. Methanol working solutions were stable for 6 months. No significant carryover was observed. The methods have been successfully implemented in the routine analysis of approximately > 1000 samples per month since March 2024.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。