A simple, rapid, and sensitive method of liquid chromatography-tandem mass spectrometry (LC/MS/MS) method was developed and validated for the determination of vardenafil in rabbit plasma. A simple protein precipitation method with ice-cold acetonitrile was used for plasma extraction. The mass transitions m/z 489⟶151 and m/z 390⟶169 were used to measure vardenafil and tadalafil (internal standard), respectively, with a total assay run time of 6 min. The limit of detection was 0.2 ng/mL. The assay was reproducible with intra-assay and interassay precision ranging 1.17%-9.17% and 1.31%-5.86%, respectively. There was also good intra-assay and interassay accuracy between 89.3%-105.3% and 94%-102% of the expected value, respectively. The linearity range was 0.5-60 ng/mL in rabbit plasma (r (2) ≥ 0.99). The measured AUC from 0 to 24 h (AUC(0 - 24t) ) for the test and reference formulations were 174.38 ± 95.91 and 176.45 ± 76.88, respectively. For the test, C (max) and T (max) were 75.36 ± 59.53 ng/mL and 1.42 ± 0.19 h, whereas, for the reference, these were 58.22 ± 36.11 ng/mL and 2.04 ± 0.33 h, respectively. The test formulation achieved a slightly lower AUC(0 - 24t) value (p > 0.05), higher C (max) values (p > 0.05), faster T (max) (p < 0.05), and almost equal bioavailability compared with the reference formulation.