Aluminum Fluoride-18 Labeled Mannosylated Dextran: Radiosynthesis and Initial Preclinical Positron Emission Tomography Studies

氟化铝-18 标记甘露糖化葡聚糖:放射合成和初步临床前正电子发射断层扫描研究

阅读:6
作者:Putri Andriana, Konstantina Makrypidi, Heidi Liljenbäck, Johan Rajander, Antti Saraste, Ioannis Pirmettis, Anne Roivainen #, Xiang-Guo Li #

Conclusions

Our results imply that Al[18F]F-NOTA-D10CM is a suitable tracer for PET imaging. Further studies in disease models with mannose receptor CD206-positive macrophages are warranted to clarify the tracer's potential for imaging of inflammation.

Procedures

D10CM was conjugated with 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) chelator and radiolabeled with the aluminum fluoride-18 method. The whole-body distribution kinetics and stability of the intravenously administered tracer were studied in healthy male Sprague-Dawley rats by in vivo PET/CT imaging, ex vivo gamma counting, and high-performance liquid chromatography analysis.

Purpose

In addition to being expressed on liver sinusoidal endothelial cells, mannose receptors are also found on antigen-presenting cells, including macrophages, which are mainly involved in the inflammation process. Dextran derivatives of various sizes containing cysteine and mannose moieties have previously been labeled with 99mTc and used for single-photon emission computed tomography imaging of sentinel lymph nodes. In this study, we radiolabeled 21.3-kDa D10CM with positron-emitting 18F for initial positron emission tomography (PET) studies in rats. Procedures: D10CM was conjugated with 1,4,7-triazacyclononane-1,4,7-triacetic acid (NOTA) chelator and radiolabeled with the aluminum fluoride-18 method. The whole-body distribution kinetics and stability of the intravenously administered tracer were studied in healthy male Sprague-Dawley rats by in vivo PET/CT imaging, ex vivo gamma counting, and high-performance liquid chromatography analysis.

Results

Al[18F]F-NOTA-D10CM was obtained with a radiochemical purity of >99% and molar activity of 9.9 GBq/μmol. At 60 minutes after injection, an average of 84% of the intact tracer was found in the blood, indicating excellent in vivo stability. The highest radioactivity concentration was seen in the liver, spleen, and bone marrow, in which mannose receptors are highly expressed under physiological conditions. The uptake specificity was confirmed with in vivo blocking experiments. Conclusions: Our results imply that Al[18F]F-NOTA-D10CM is a suitable tracer for PET imaging. Further studies in disease models with mannose receptor CD206-positive macrophages are warranted to clarify the tracer's potential for imaging of inflammation.