Development of Visually Indistinguishable Acoustic Coupling Pads for Double-Blind Focused Ultrasound Neuromodulation Studies

开发用于双盲聚焦超声神经调控研究的视觉上无法区分的声耦合垫

阅读:1

Abstract

BACKGROUND: Transcranial focused ultrasound (tFUS) is an emerging noninvasive neuromodulation modality with the ability to target deep brain structures with high spatial precision. Despite its promise, rigorous evaluation of its efficacy is limited by the absence of reliable, fully double-blind sham methodologies. OBJECTIVE: To develop and validate a pair of visually and mechanically indistinguishable acoustic coupling pads that enable true double-blind tFUS neuromodulation studies by providing either efficient ultrasound transmission or robust ultrasound blocking without altering participant or operator experience. METHODS: Two coupling pads were engineered: a transmitting pad designed to allow <5% pressure amplitude loss relative to free-water propagation, and a non-transmitting pad designed to attenuate ultrasound by ≥40 dB. Both pads used a Dragon Skin 10 NV silicone base and were identical in size, appearance, flexibility, and handling. The non-transmitting pad incorporated an encapsulated air-based blocking layer using an open-cell polyethylene foam insert. Acoustic performance was evaluated in a water tank using a 650 kHz BrainSonix transducer and a calibrated needle hydrophone. Sound speed of the silicone material was measured using pulse-echo techniques. RESULTS: Twenty-three matched transmitting and non-transmitting pad pairs were fabricated and tested. Transmitting pads demonstrated a mean attenuation of -0.41 ± 0.53 dB, satisfying the design criterion of minimal acoustic loss. Non-transmitting pads demonstrated a mean attenuation of -48.61 ± 4.33 dB, exceeding the required -40 dB threshold for effective sham conditions. The Dragon Skin 10 NV substrate exhibited a sound speed of 964.72 m/s and produced <2 mm axial focal shift for standard pad thicknesses, with no measurable change in focal width. Both pad types were visually and tactually indistinguishable, could not be differentiated by experienced operators or participants, and maintained mechanical integrity after repeated cleaning. CONCLUSION: These acoustically engineered coupling pads provide a practical and validated solution for achieving true single- and double-blind conditions in tFUS neuromodulation studies. By preserving identical sensory and procedural experiences while enabling precise control over ultrasound transmission, this approach addresses a critical methodological gap in human ultrasound neuromodulation research.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。