A Method for Electrical Stimulus Artifact Removal Exploiting Neural Refractoriness: Validation by Contrasting Cathodic and Anodic Stimulation

利用神经不应期去除电刺激伪迹的方法:通过对比阴极刺激和阳极刺激进行验证

阅读:1

Abstract

OBJECTIVE: To present a novel method for removing stimulus transient that exploits the absolute refractory period of electrically excitable neural tissues. BACKGROUND: Electrical stimulation often generates significant signal artifacts that can obscure important physiological signals. Removal of the artifact and understanding latent information from these signals could provide objective measures of circuit engagement, potentially driving advancements in neuromodulation research and therapies. METHODS: We conducted intracranial physiology studies on five consecutive patients with Parkinson's disease who underwent deep brain stimulation (DBS) surgery as part of their routine care. Monopolar stimuli (either cathodic or anodic) were delivered in pairs through the DBS electrode across a range of inter-stimulus intervals. Recordings from adjacent unused electrode contacts used broadband sampling and precise synchronization to generate a robust template for the stimulus transient during the absolute refractory period. These templates of stimulus transient were then subtracted from recordings at different intervals to extract and analyze the residual neural potentials. RESULTS: After artifact removal, the residual signals exhibited absolute and relative refractory periods with timing indicative of neural activity. Cathodic and anodic DBS pulses generated distinct patterns of local tissue activation, showing phase independence from the prior stimulus. The earliest detectable neural responses occurred at short peak latencies (ranging from 0.19 to 0.38 ms post-stimulus) and were completely or partially obscured by the stimulus artifact prior to removal. Cathodic stimuli produced stronger local tissue responses than anodic stimuli, aligning with clinical observations of lower activation thresholds for cathodic stimulation. However, cathodic and anodic pulses induced artifact patterns that were equivalent but opposite. INTERPRETATION: The proposed artifact removal technique enhances prior approaches by allowing direct measurement of local tissue responses without requirements for stimulus polarity reversal, template scaling, or specialized filters. This approach could be integrated into future neuromodulation systems to visualize stimulus-evoked neural potentials that would otherwise be obscured by stimulus artifacts.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。