Durable multimodal and holistic response for physiologic closed-loop spinal cord stimulation supported by objective evidence from the EVOKE double-blind randomized controlled trial

EVOKE双盲随机对照试验的客观证据支持了生理闭环脊髓刺激可产生持久的多模式和整体性反应。

阅读:1

Abstract

INTRODUCTION: Chronic pain patients may experience impairments in multiple health-related domains. The design and interpretation of clinical trials of chronic pain interventions, however, remains primarily focused on treatment effects on pain intensity. This study investigates a novel, multidimensional holistic treatment response to evoked compound action potential-controlled closed-loop versus open-loop spinal cord stimulation as well as the degree of neural activation that produced that treatment response. METHODS: Outcome data for pain intensity, physical function, health-related quality of life, sleep quality and emotional function were derived from individual patient level data from the EVOKE multicenter, participant, investigator, and outcome assessor-blinded, parallel-arm randomized controlled trial with 24 month follow-up. Evaluation of holistic treatment response considered whether the baseline score was worse than normative values and whether minimal clinical important differences were reached in each of the domains that were impaired at baseline. A cumulative responder score was calculated to reflect the total minimal clinical important differences accumulated across all domains. Objective neurophysiological data, including spinal cord activation were measured. RESULTS: Patients were randomized to closed-loop (n=67) or open-loop (n=67). A greater proportion of patients with closed-loop spinal cord stimulation (49.3% vs 26.9%) were holistic responders at 24-month follow-up, with at least one minimal clinical important difference in all impaired domains (absolute risk difference: 22.4%, 95% CI 6.4% to 38.4%, p=0.012). The cumulative responder score was significantly greater for closed-loop patients at all time points and resulted in the achievement of more than three additional minimal clinical important differences at 24-month follow-up (mean difference 3.4, 95% CI 1.3 to 5.5, p=0.002). Neural activation was three times more accurate in closed-loop spinal cord stimulation (p<0.001 at all time points). CONCLUSION: The results of this study suggest that closed-loop spinal cord stimulation can provide sustained clinically meaningful improvements in multiple domains and provide holistic improvement in the long-term for patients with chronic refractory pain. TRIAL REGISTRATION NUMBER: NCT02924129.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。