Automatic failure mode evaluation using non-linear phase contrast correction to improve flow measurement accuracy in cardiovascular magnetic resonance phase contrast imaging

利用非线性相位对比校正进行自动故障模式评估,以提高心血管磁共振相位对比成像中的血流测量精度

阅读:1

Abstract

BACKGROUND: Phase contrast (PC) cardiovascular magnetic resonance (CMR) is clinically used to quantify flow. The quantification accuracy is diminished by background phase errors. Image-based background phase correction algorithms are commercially available, but their accuracy is still under evaluation. Here, we validate a recently developed non-linear phase contrast correction (nPCcor) algorithm that includes automatic failure mode classification in a large single-vendor multi-scanner retrospective study. METHODS: Three hundred forty-six through-plane PC images at the aortic valve (AAo) and pulmonary artery (PA) were acquired on three different GE HealthCare 1.5T clinical MRI scanners. Each PC scan was repeated on a static phantom, and the static phantom-corrected PC series was considered as the reference standard. Two image-based static tissue background phase corrections were applied on each PC series: a linear and the nPCcor. Accuracy of nPCcor was studied by comparing the net flow in the vessel of interest for the uncorrected, linear-corrected, and nPCcor images with respect to the static phantom-corrected series. Accuracy was defined as a difference in net flow ≤10% with respect to the static phantom corrected net flow. RESULTS: Flow measurements using the nPCcor images after nPCcor automatic classification were found to be accurate for 87% (281/323) of PC datasets, 6% and 17% better than using uncorrected and linear-corrected (p<0.05), respectively. Most importantly, nPCcor was able to correctly identify 70% (16/23) PC cases likely to provide inaccurate flow measurements. Flow measurements after nPCcor in the scanner with the largest phase offsets were found to be accurate for 74% (62/84) of PC datasets, 22% better than using the uncorrected images (p<0.05). nPCcor correction was statistically significant more accurate than linear correction for all scanners (p<0.05). The percentage of regurgitation reclassification of ≥1 category decreased to 8% (8/323) after nPCcor correction, 3% better than for uncorrected images. CONCLUSION: nPCcor with automatic failure mode evaluation improved accuracy with respect to no correction and linear correction and successfully identified PC scans that are likely to result in unreliable flow measurements. nPCcor performance and phase offset errors varied greatly among scanners using the same CMR protocol. nPCcor has higher impact in scanners exhibiting the largest background phase offsets. TRIAL REGISTRATION: observational study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。