Factors influencing image quality in fetal cardiovascular magnetic resonance cine imaging using Doppler ultrasound gating: A multicenter study

影响胎儿心血管磁共振电影成像(采用多普勒超声门控)图像质量的因素:一项多中心研究

阅读:1

Abstract

BACKGROUND: Fetal cine cardiovascularmagnetic resonance (CMR) is an emerging technique for evaluating the fetal heart in conditions such as congenital heart disease, but limited evidence on factors affecting image quality restricts its clinical potential. This study investigated key determinants of image quality in a multicenter cohort. METHODS: This study analyzed fetal CMR scans from April 2021 to July 2023 at three centers (University Hospital Bonn, Children's Hospital Colorado, Phoenix Children's Hospital). Cine image quality was assessed using a 5-point Likert scale (1=non-diagnostic to 5=excellent) across three criteria as follows: contour sharpness, blood-to-structure contrast, and artifacts. Overall image quality scores were calculated by the average of all criteria. Apparent signal-to-noise (aSNR) and contrast-to-noise ratios (aCNR) were measured. Nine parameters were evaluated for their impact on image quality, namely: gestational age, body mass index (BMI), fetal motion, patient positioning, gating signal stability, breathing technique, field strength, slice thickness, and flip angle. Comparisons were conducted using the Mann-Whitney U test. RESULTS: A total of 98 scans were analyzed. Higher overall image quality, aSNR, and aCNR were observed in participants with BMI <30 kg/m², gestational age ≥32 weeks, low fetal motion severity, and stable gating signals (e.g., overall image quality for BMI <30 kg/m² vs ≥30 kg/m²: 4.4±0.7 vs. 4.1±0.7, p<0.001). Supine positioning resulted in better overall image quality compared to the left lateral position (4.5±0.5 vs. 4.2±0.8, p=0.001). Breath-holds provided similar overall image quality but improved contour sharpness and reduced artifacts compared to free breathing (5 [4,5] vs. 4 [4,5], p=0.042; and 4 [3-5] vs. 4 [3-5], p=0.014, respectively). At 1.5T field strength, higher contrast and fewer artifacts were observed compared to 3T (5 [4,5] vs. 5 [4,5], p=0.041; and 4 [4,5] vs. 4 [3-5], p=0.010, respectively). Slice thickness showed no significant impact on image quality. CONCLUSION: Various factors (e.g. BMI) influence fetal cardiac cine MRI image quality. Understanding these factors may help achieving reliable examinations and better exploit the potential of fetal cardiac MRI in clinical routine.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。