Clinical, Experimental, and Computational Validation of a New Doppler-Based Index for Coarctation Severity Assessment

基于多普勒的新型主动脉缩窄严重程度评估指标的临床、实验和计算验证

阅读:1

Abstract

BACKGROUND: Long-term morbidity including hypertension often persists in coarctation patients despite current guidelines. Coarctation severity can be invasively assessed via peak-to-peak catheter pressure gradient (PPCG), which is estimated noninvasively via simplified Bernoulli equation and conventionally reported as peak instantaneous Doppler gradient (PIDG). However, underlying simplifications of the equation limit diagnostic accuracy. We studied the diagnostic performance of a new Doppler-based diastolic index called the continuous flow pressure gradient (CFPG) versus conventional indices in assessing coarctation severity. METHODS: In a rabbit model mimicking human aortic coarctation, temporal blood pressure waveforms revealed the diastolic instantaneous pressure gradients and spectral Doppler features impacted by coarctation severity. We therefore hypothesized that CFPG provides superior correlation with coarctation gradients measured invasively. PIDG and CFPG were quantified using color flow echocardiography in humans and rabbits with discrete coarctations. Results were compared with PPCG in rabbits (n = 34) and arm-leg systolic gradients (n = 25) in humans via 1-way analysis of variance, Pearson's correlation, linear regression, and Bland-Altman analysis. RESULTS: A threshold of CFPG ≥ 4.6 mm Hg was identified via the Youden index as representative of PPCG ≥ 20 mm Hg (the current guideline value for coarctation intervention) in rabbits, while a CFPG ≥1.0 mm Hg represented an arm-leg systolic gradient ≥20 mm Hg in humans. Accuracy measures revealed superior correlation of CFPG (R(2) > 0.80) and mild receiver operating characteristic improvement (area under the receiver operating characteristic curve, 0.94-0.95) compared with PIDG (R(2) < 0.63; area under the receiver operating characteristic curve, 0.89-0.95). Inter-/intraobserver variability tested by intraclass correlation coefficient revealed measurement reliability with differences ≤8.2% and 10.7%, respectively. Computational simulations of anesthetized versus conscious hemodynamics showed parameters were minimally impacted by isoflurane inherent in the data used to derive CFPG. These results confirm the potential diagnostic accuracy of CFPG in echocardiography-based coarctation severity assessment. We are optimistic that CFPG will be useful for translation of results from preclinical studies that revisit current guidelines to limit morbidity in humans with aortic coarctation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。