Development and validation of a liquid chromatography coupled to a diode array detector (LC-DAD) method for measuring mitotane (DDD) in plasma samples

开发并验证了一种液相色谱-二极管阵列检测器(LC-DAD)联用方法,用于测定血浆样品中的米托坦(DDD)含量。

阅读:1

Abstract

INTRODUCTION: Mitotane (o,p'-DDD) is the drug of choice for Adrenocortical Carcinomas (ACC) and its measurement in plasma is essential to control drug administration. OBJECTIVE: To develop and validate a simple, reliable and straightforward method for mitotane determination in plasma samples. METHOD: Drug-free plasma samples were collected in potassium-ethylenediamine tetraacetate (K-EDTA) tubes and spiked with 1.0, 2.5, 10.0, 25.0 and 50.0 µg/mL of mitotane (DDD). The p,p'-DDD was used as an Internal Standard (IS) and was added at 25.0 µg/mL concentration to all samples, standards and controls. Samples were submitted to protein precipitation with acetonitrile and then centrifuged. 50 uL of the supernatant was injected into an HPLC system coupled to a Diode Array Detector (DAD). DDD and IS were detected at 230 nm in a 12 min isocratic mode with a solvent mixture of 60 % acetonitrile and 40 % formic acid in water with 0.1 % pump mixed, at 0.6 mL/min flow rate, in a reversed-phase (C18) chromatographic column kept at 28°C. The sensitivity, selectivity, precision, presence of carry-over, recovery and matrix-effect, linearity, and method accuracy were evaluated. RESULTS: The present study's method resulted in a symmetrical peak shape and good baseline resolution for DDD (mitotane) and 4,4'-DDD (internal standard) with retention times of 6.0 min, 6.4 mim, respectively, with resolutions higher than 1.0. Endogenous plasma compounds did not interfere with the evaluated peaks when blank plasma and spiked plasma with standards were compared. Linearity was assessed over the range of 1.00-50.00 µg/mL for mitotane (R2 > 0.9987 and a 97.80 %‒105.50 % of extraction efficiency). Analytical sensitivity was 0.98 µg/mL. Functional sensitivity (LOQ) was 1.00 µg/L, intra-assay and inter-assay coefficient of variations were less than 9.98 %, and carry-over was not observed for this method. Recovery ranged from 98.00 % to 117.00 %, linearity ranged from 95.00 % to 119.00 %, and high accuracy of 89.40 % to 105.90 % with no matrix effects or interference was observed for mitotane measurements. Patients' sample results were compared with previous measurements by the GC-MS method with a high correlation (r = 0.88 and bias = -10.20 %). CONCLUSION: DDD determination in plasma samples by the developed and validated method is simple, robust, efficient, and sensitive for therapeutic drug monitoring and dose management to achieve a therapeutic index of mitotane in patients with adrenocortical cancer.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。