Left Ventricular Mass Assessment by 1- and 2-Dimensional Echocardiographic Methods in Hemodialysis Patients: Changes in Left Ventricular Volume Using Echocardiography Before and After a Hemodialysis Session

采用一维和二维超声心动图方法评估血液透析患者左心室质量:血液透析前后超声心动图测量左心室容积的变化

阅读:1

Abstract

RATIONALE & OBJECTIVE: Left ventricular (LV) mass (LVM) is a predictor of cardiovascular morbidity and mortality and commonly calculated using 1-dimensional (1D) echocardiographic methods. These methods are vulnerable to small measurement errors and LVM may wrongly change according to changes in LV volume (LVV). Less commonly used 2-dimensional (2D) methods can accommodate to the changes in LVV and may be a better alternative among patients receiving hemodialysis (HD) with large fluid fluctuations. STUDY DESIGN: Observational study. SETTING & PARTICIPANTS: Patients with end-stage kidney disease receiving HD. EXPOSURE: One HD session. ANALYTICAL APPROACH: Transthoracic echocardiography was performed right before and after HD. LVM was calculated using 1D (Devereux, Penn, and Teichholz) and 2D methods (truncated ellipsoid and area-length). OUTCOMES: Significant differences in LVM after HD. RESULTS: We compared dimensions, LVV and LVM, in 53 patients (mean age, 63 ± 15 years; 66% men). For each 1-L increase in ultrafiltration volume (UFV), LV internal diameter decreased 1.1 mm (95% CI, 0.5-1.7 mm; P = 0.001). Patients were divided into 2 groups by the median UFV of 1.6 L. Patients with UFV > 1.6 L had significant smaller LVV and LV internal diameter after HD. LVM calculated using 1D methods decreased according to changes in LVV. Conversely, LVM calculated using 2D methods was not significantly different after HD. No significant change in differences between diastolic - systolic myocardial thickness or LVM as assessed using 1D and 2D methods was observed before and after HD, indicating that LVM remained constant despite HD. LIMITATIONS: We did not use contrast enhancement, 3-dimensional methods, or cardiac magnetic resonance. CONCLUSIONS: LVM calculated using 2D methods, truncated ellipsoid and area-length, is less affected by fluctuations in fluid and LVV, in contrast to 1D methods. Complementary LVM calculation using 2D methods is encouraged, especially in patients with large fluid fluctuations in which increased LVM using a 1D method has been detected.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。