Validation of Tracheal Sound-Based Respiratory Effort Monitoring for Obstructive Sleep Apnoea Diagnosis

基于气管音的呼吸努力监测在阻塞性睡眠呼吸暂停诊断中的验证

阅读:1

Abstract

Background: Respiratory effort is considered important in the context of the diagnosis of obstructive sleep apnoea (OSA), as well as other sleep disorders. However, current monitoring techniques can be obtrusive and interfere with a patient's natural sleep. This study examines the reliability of an unobtrusive tracheal sound-based approach to monitor respiratory effort in the context of OSA, using manually marked respiratory inductance plethysmography (RIP) signals as a gold standard for validation. Methods: In total, 150 patients were trained on the use of type III cardiorespiratory polygraphy, which they took to use at home, alongside a neck-worn AcuPebble system. The respiratory effort channels obtained from the tracheal sound recordings were compared to the effort measured by the RIP bands during automatic and manual marking experiments. A total of 133 central apnoeas, 218 obstructive apnoeas, 263 obstructive hypopneas, and 270 normal breathing randomly selected segments were shuffled and blindly marked by a Registered Polysomnographic Technologist (RPSGT) in both types of channels. The RIP signals had previously also been independently marked by another expert clinician in the context of diagnosing those patients, and without access to the effort channel of AcuPebble. The classification achieved with the acoustically obtained effort was assessed with statistical metrics and the average amplitude distributions per respiratory event type for each of the different channels were also studied to assess the overlap between event types. Results: The performance of the acoustic effort channel was evaluated for the events where both scorers were in agreement in the marking of the gold standard reference channel, showing an average sensitivity of 90.5%, a specificity of 98.6%, and an accuracy of 96.8% against the reference standard with blind expert marking. In addition, a comparison using the Embla Remlogic 4.0 automatic software of the reference standard for classification, as opposed to the expert marking, showed that the acoustic channels outperformed the RIP channels (acoustic sensitivity: 71.9%; acoustic specificity: 97.2%; RIP sensitivity: 70.1%; RIP specificity: 76.1%). The amplitude trends across different event types also showed that the acoustic channels exhibited a better differentiation between the amplitude distributions of different event types, which can help when doing manual interpretation. Conclusions: The results prove that the acoustically obtained effort channel extracted using AcuPebble is an accurate, reliable, and more patient-friendly alternative to RIP in the context of OSA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。