Suggestions for global coagulation assays for the assessment of COVID-19 associated hypercoagulability

针对 COVID-19 相关高凝状态的全球凝血检测建议

阅读:7
作者:Tom W van de Berg, Anne-Marije M Hulshof, Magdolna Nagy, Rene van Oerle, Jan-Willem Sels, Bas van Bussel, Hugo Ten Cate, Yvonne Henskens, Henri M H Spronk; Dutch Covid-19 and Thrombosis Coalition (DCTC)

Conclusion

Thrombin generation and tPA-ROTEM protocols for measurements in the COVID-19 populations were adjusted and validated. The adjusted thrombin generation assay shows good sensitivity for measurements in heparin spiked plasma. High levels of fibrinogen did not alter the assay or the effectiveness of heparins as measured in this assay. t-PA ROTEM was effective in measurement of both high fibrinogen and heparins spiked samples and was sensitive to the expected relevant coagulant changes by these conditions. No clear fibrinolytic effect was observed in different conditions.

Methods

Calibrated Automated Thrombography (CAT) was optimized to assess plasma thrombin generation in the presence of heparins. The final conditions with either 10 μg/mL Ellagic acid (EA) or PPP Reagent HIGH (high tissue factor; HPPH) were validated according to the EP5 protocol for within-run and between-run variability. Overall variability was well below 10%. To estimate the influences of heparins and high fibrinogen levels, CAT was performed on spiked plasma aliquots from 13 healthy volunteers. Comparable to the CAT method, tPA-ROTEM was used to validate the effect of high fibrinogen and heparins on clotting time, clot firmness and clot lysis parameters.

Results

Our adjusted COVID-19 assay showed a heparin dose dependent decrease in peak height and endogenous thrombin potential (ETP) for both EA and HPPH triggered variants. High fibrinogen did not alter the inhibitory effect of either LMWH or UFH, nor did it influence the peak height or ETP in any of the conditions. The tPA-ROTEM showed a significant prolongation in clotting time with the additions of heparin, which normalized with the addition of high fibrinogen. MCF was markedly increased in all hyperfibrinogenemic conditions. A trend towards increased lysis time and, thus, decreased fibrinolysis was observed.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。