Comparison Between Pathogen Associated Laboratory and Clinical Parameters in Early-Onset Sepsis of the Newborn

新生儿早期败血症病原体相关实验室指标与临床指标的比较

阅读:1

Abstract

OBJECTIVES: To identify laboratory and clinical characteristics of different pathogens associated with early-onset sepsis (EOS) of the newborn. METHODS: Newborns with EOS were retrospectively analyzed regarding laboratory and clinical parameters associated with the identified pathogen. RESULTS: We identified 125 newborns having diagnosis of culture proven EOS between 1993 and 2011. One hundred cases had diagnosis of group B streptococci (GBS) infection (80%), 11 had Escherichia coli (8.8%), eight enterococci (6.4%), and six other pathogens (4.8%). White blood cell count (WBC), immature to total neutrophil (IT) ratio, and C-reactive protein (CRP) values did not differ between groups within the first 72 hours of life. Presence of high (>30000/µL) and low (<9000/µl) WBC was significantly less found compared with IT-ratio >0.2 in GBS and E.coli EOS. High WBC were more common found than low WBC in all groups. Gram positive pathogens were more common found in late preterm and term infants (84%), and gram negative pathogens more common in very low birth weight infants (64%). E. coli was significantly associated with lower gestational age and birth weight, respectively. CONCLUSION: An abnormal IT-ratio was a more common finding than an abnormal WBC in GBS and E. coli EOS. E. coli was significantly associated with prematurity.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。