Artificial intelligence to automatically measure on radiographs the postoperative positions of the glenosphere and pivot point after reverse total shoulder arthroplasty

利用人工智能技术自动测量反向全肩关节置换术后X光片上肩胛盂球和枢轴点的术后位置

阅读:1

Abstract

BACKGROUND: Radiographic evaluation of the implant configuration after reverse total shoulder arthroplasty (rTSA) is a time-consuming task that is frequently subject to interobserver disagreement. Deep learning (DL) artificial intelligence algorithms have previously demonstrated high accuracy when analyzing relevant angles to determine rTSA distalization and lateralization, as well as glenoid inclination and humeral alignment. The goal of this study is to build on this existing work to automatically measure the postoperative radiographic location of the glenosphere center of rotation (GCR) and the pivot point (PP) in reference to the scapula. METHODS: A total of 417 primary rTSA postoperative anteroposterior radiographs were retrieved and utilized for this study. Five measurements were designed and manually performed by 3 observers: (1) the medial position and (2) the inferior position of the geometric center of rotation of the glenosphere (glenosphere center of rotation medialization [GCRm] and glenosphere center of rotation inferiorization [GCRi], respectively) relative to the most lateral aspect of the inferior acromion, as well as (3) the projection of the PP to GCR vector on the fossa line (PP projection), (4) the distance between GCR and glenoid (GCR-glenoid distance), and (5) the overall glenoid lateral offset (GLO). Subsequently, a DL algorithm was developed to automatically segment the radiograph and perform the same measurements described above. All measurements were corrected for radiographic magnification using the known glenosphere diameter for each shoulder. Intraclass Correlation Coefficients (ICCs) were calculated to assess interobserver and DL-human agreements on all measurements. RESULTS: The DL algorithm achieved an average Dice Coefficient of 0.86, indicating good segmentation accuracy. The ICCs (95% confidence interval) amongst human observers were 0.86 (0.81-0.90) for the GCRm, 0.93 (0.9-0.95) for the GCRi, 0.95 (0.92-0.96) for the PP projection, 0.85 (0.79-0.89) for GCR-glenoid distance, and 0.92 (0.88-0.95) for GLO. The ICCs between the DL-derived measurements and the average of manual measurements were 0.95 (0.92-0.96) for the GCRm, 0.90 (0.84-0.93) for the GCRi, 0.96 (0.94-0.98) for the PP projection, 0.91 (0.87-0.94) for GCR-glenoid distance, and 0.92 (0.88-0.95) for GLO. The DL algorithm automatically analyzed each testing image in 2 seconds. CONCLUSION: The developed DL algorithm can automatically measure the location of the glenosphere geometric center of rotation and the location of the PP on postoperative radiographs obtained after primary rTSA. Agreement between DL-derived measures and those from human observers was high. This DL algorithm adds to the armamentarium of tools available for automatic assessment of final implant position on radiographs after rTSA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。