Automatic segmentation of calibration device boundaries on ophthalmic optical biometry instruments in optical coherence tomography images

在光学相干断层扫描图像中自动分割眼科光学生物测量仪器上的校准装置边界

阅读:1

Abstract

BACKGROUND: As the use of ophthalmic optical biometers in clinical practice has increased, so too has the demand for higher standards in evaluating ocular metrics. Among these metrics, the measurement of the ocular axial length (AL) is a critical task that often requires calibrated devices. Thus, efficient algorithms need to be developed to improve calibration mechanisms and ensure precise measurements. This study aimed to establish an algorithm to determine the pixel heights (PHs) of the boundary vertices of a calibration device in ophthalmic optical biometers to improve the accuracy and repeatability of ocular AL measurements in optical coherence tomography (OCT) images. METHODS: The algorithm employs a series of image morphological processing techniques to delineate the rough boundaries of the calibration device in OCT images. After extracting boundary points, clustering techniques are applied to simplify the data. These clustered boundary points are analyzed for characteristic parameters to refine the boundaries. Finally, a fitting process is used to determine the PHs of the vertices, and performance is then evaluated by tests measuring the repeatability and recognition accuracy of the algorithm. RESULTS: The proposed method had high repeatability in locating the boundaries of the front and rear sections of the calibration device, and had repeatability deviations not exceeding 0.36 pixels and 0.18 pixels, respectively. Additionally, linear fitting of the computed sub-PH and optical path difference yielded determination coefficients of 0.9998330 and 0.9999863, respectively, indicating an almost perfectly linear relationship. This high degree of linearity demonstrates the exceptional accuracy of the method in locating the calibration device boundaries. These results provide a heuristic approach for the future boundary localization of calibration devices in OCT images for biometers, offering a robust and reliable framework for enhancing calibration precision in ophthalmic optical biometry. CONCLUSIONS: The developed algorithm provides an effective and reliable method for determining the PHs of calibration device vertices in ophthalmic optical biometers. With its high accuracy and repeatability, this valuable tool could enhance ocular AL measurements and improve the overall quality of ocular assessments in clinical practice.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。