Evaluating auto-contouring accuracy in reduced CT dose images for radiopharmaceutical therapies: Denoising and evaluation of (177)Lu DOTATATE therapy dataset

评估放射性药物治疗中低剂量CT图像的自动勾画精度:(177)Lu DOTATATE治疗数据集的去噪和评估

阅读:2

Abstract

PURPOSE: Reducing radiation dose attributed to computed tomography (CT) may compromise the accuracy of organ segmentation, an important step in (177)Lu DOTATATE therapy that affects both activity and mass estimates. This study aimed to facilitate CT dose reduction using deep learning methods for patients undergoing serial single photon emission computed tomography (SPECT)/CT imaging during (177)Lu DOTATATE therapy. METHODS: The (177)Lu DOTATATE patient dataset hosted in Deep Blue Data was used in this study. The noise insertion method incorporating the effect of bowtie filter, automatic exposure control, and electronic noise was applied to simulate images at four reduced dose levels. Organ segmentation was carried out using the TotalSegmentator model, while image denoising was performed with the DenseNet model. The impact of segmentation performance on the dosimetry accuracy of (177)Lu DOTATATE therapy was quantified by calculating the percent difference between a dose rate map segmented with a reference mask and the same dose rate map segmented with a test mask (PD(dose)) for spleen, right kidney, left kidney, and liver. RESULTS: Before denoising, the mean ± standard deviation of PD(dose) for all critical organs were 2.31 ± 2.94%, 4.86 ± 9.42%, 8.39 ± 14.76%, 12.95 ± 19.99% in CT images at dose levels down to 20%, 10%, 5%, 2.5% of the normal dose, respectively. After denoising, the corresponding results were 1.69 ± 2.25%, 2.84 ± 4.46%, 3.72 ± 4.22%, 7.98 ± 15.05% in CT images at dose levels down to 20%, 10%, 5%, 2.5% of the normal dose, respectively. CONCLUSION: As dose reduction increased, CT image segmentation gradually deteriorated, which in turn deteriorated the dosimetry accuracy of (177)Lu DOTATATE therapy. Improving CT image quality through denoising could enhance (177)Lu DOTATATE dosimetry, making it a valuable tool to support CT dose reduction for patients undergoing serial SPECT/CT imaging during treatment.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。