A deep learning algorithm for the detection of aortic dissection on non-contrast-enhanced computed tomography via the identification and segmentation of the true and false lumens of the aorta

一种基于深度学习的算法,通过识别和分割主动脉的真假管腔,在非增强CT图像上检测主动脉夹层。

阅读:1

Abstract

BACKGROUND: Aortic dissection is a life-threatening clinical emergency, but it is often missed and misdiagnosed due to the limitations of diagnostic technology. In this study, we developed a deep learning-based algorithm for identifying the true and false lumens in the aorta on non-contrast-enhanced computed tomography (NCE-CT) scans and to ascertain the presence of aortic dissection. Additionally, we compared the diagnostic performance of this algorithm with that of radiologists in detecting aortic dissection. METHODS: We included 320 patients with suspected acute aortic syndrome from three centers (Beijing Anzhen Hospital Affiliated to Capital Medical University, Fujian Provincial Hospital, and Xiangya Hospital of Central South University) between May 2020 and May 2022 in this retrospective study. All patients underwent simultaneous NCE-CT and contrast-enhanced CT (CE-CT). The cohort comprised 160 patients with aortic dissection and 160 without aortic dissection. A deep learning algorithm, three-dimensional (3D) full-resolution U-Net, was continuously trained and refined to segment the true and false lumens of the aorta to determine the presence of aortic dissection. The algorithm's efficacy in detecting dissections was evaluated using the receiver operating characteristic (ROC) curve, including the area under the curve (AUC), sensitivity, and specificity. Furthermore, a comparative analysis of the diagnostic capabilities between our algorithm and three radiologists was conducted. RESULTS: In diagnosing aortic dissection using NCE-CT images, the developed algorithm demonstrated an accuracy of 93.8% [95% confidence interval (CI): 89.8-98.3%], a sensitivity of 91.6% (95% CI: 86.7-95.8%), and a specificity of 95.6% (95% CI: 91.2-99.3%). In contrast, the radiologists achieved an accuracy of 88.8% (95% CI: 83.5-94.1%), a sensitivity of 90.6% (95% CI: 83.5-94.1%), and a specificity of 94.1% (95% CI: 72.9-97.6%). There was no significant difference between the algorithm's performance and radiologists' mean performance in accuracy, sensitivity, or specificity (P>0.05). CONCLUSIONS: The algorithm proficiently segments the true and false lumens in aortic NCE-CT images, exhibiting diagnostic capabilities comparable to those of radiologists in detecting aortic dissection. This suggests that the algorithm could reduce misdiagnoses in clinical practice, thereby enhancing patient care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。