Toward Patient-Centric Digital Monitoring of Obstructive Sleep Apnea: Mixed Methods Study

面向患者的阻塞性睡眠呼吸暂停数字化监测:混合方法研究

阅读:3

Abstract

BACKGROUND: Obstructive sleep apnea (OSA) is a sleep disorder characterized by repeated breathing disruptions during sleep. Remote patient monitoring (RPM) of OSA is important, yet contemporary methods are limited. Sensor-based digital health technologies (sDHTs) promise a step advance in OSA RPM, but must provide meaningful, actionable, and usable outputs for patients. While the centrality of considering patient views in sDHT development is widely acknowledged, patient perspectives and priorities are rarely assessed. OBJECTIVE: This study aimed to identify patient-prioritized health aspects and preferences for digital measures and RPM to enhance OSA care quality and patient experience, guided by the digital measures that matter framework. METHODS: We used a mixed methods design combining quantitative and qualitative approaches. Individuals with a formal OSA diagnosis and persistent sleep problems (n=223) completed a survey in which they ranked items related to treatment burdens and health priorities, and responded to open-ended questions about restoring previous quality-of-life elements and desired health goals. To gain deeper qualitative insights, we conducted semistructured interviews with patients with OSA, patient advocates, and health care professionals (n=11), focusing on follow-up care, attitudes toward sDHTs and RPM, and preferences for future OSA-related sDHTs and metrics. Quantitative data were analyzed using bootstrap-aggregated Borda counts (broad support) and Plackett-Luce modeling (intense prioritization), while qualitative data from surveys and interviews were analyzed thematically. RESULTS: Key meaningful aspects of health included the improvement of subjective sleep quality (top-ranked burden; health goal for 46.5%, 93/200 of participants), an increase in daytime energy (quality-of-life aspect to restore for 35.6%, 72/202 and health goal for 25.5%, 51/200 of participants), and physical activity (quality-of-life aspect to restore for 24.7%, 50/202 and health goal for 16.5%, 33/200 of participants). Sleep characteristics and daytime energy were priority targets for digital measure development. Smartwatches, sleep mats, and smart rings were preferred modalities for integration into RPM. Participants' priorities for enhancing monitoring included (1) expanding metrics beyond the Apnea-Hypopnea Index (AHI; 36.6%, 52/142), (2) improving measurement accuracy (20.4%, 29/142), and (3) ensuring outputs are meaningful, understandable (18.3%, 26/142), and actionable (9.2%, 13/142). Patients also reported difficulty interpreting RPM data to determine if and when follow-up care is needed and what type of care is appropriate. CONCLUSIONS: RPM solutions for OSA should expand beyond AHI, ensure accuracy and interpretability, and provide actionable insights to support comprehensive patient-centric management.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。