Reproducibility of circumferential strain on cine displacement encoding with stimulated echoes magnetic resonance imaging before and after contrast at 3T

在3T磁共振成像中,对比剂注射前后,采用刺激回波序列进行电影位移编码,测量环向应变的可重复性。

阅读:2

Abstract

BACKGROUND: Magnetic resonance imaging (MRI) with displacement encoding with stimulated echoes (DENSE) is well recognized for accurate and precise quantification of myocardial displacement and strain, but its reproducibility before and after contrast injection has not been investigated. Gadolinium is the most widely used contrast agent. Ferumoxytol is increasingly used off-label in specific patient groups. We aim to assess the reproducibility of cine DENSE MRI to measure global and segmental circumferential myocardial strain (E(CC)) before and after contrast injection for gadolinium and ferumoxytol, respectively. METHODS: All imaging was conducted using 3T scanners. In 11 patients with cardiac disease, breath-hold two-dimensional cine DENSE was acquired in a mid-ventricular short-axis slice before and following the injection of gadolinium (0.1 mmol/kg). A separate cohort of 11 subjects (5 healthy subjects and 6 patients with ischemic heart disease) received 3 incremental doses of ferumoxytol: 0.125, 1.875, and 2.0 mg/kg (to a cumulative dose of 4.0 mg/kg). The same DENSE acquisition was performed before and after each incremental dose. Post-processing generated left ventricular (LV) displacement and E(CC) maps, and strain-time curves. Global and segmental E(CC) in six mid-level short-axis LV segments were compared. Signal-to-noise (SNR) was evaluated on the magnitude images throughout the cardiac cycle in the myocardium, liver, and back muscle, respectively. A Bayesian analysis was performed to test results with region of practical equivalence (ROPE) at ±5 for SNR and ±0.02 for E(CC) (p < 0.05 as significant). RESULTS: Based on the percentage within the ROPE and the corresponding p-values, global E(CC) exhibited excellent practical equivalence under pre- and post-contrast conditions for gadolinium (p = 0.413) and ferumoxytol (p ≥ 0.161). Segmental E(CC) reproducibility was consistently high across all comparative analyses, with at least 87.02% falling within the ROPE. Gadolinium administration significantly improved SNR in all tissues during the early systolic phases (1-5, p ≤ 0.021). Ferumoxytol resulted in a reduction in liver SNR during diastolic phases (10-20, p ≤ 0.011) and a significant increase in myocardium SNR during systolic phases (1-5, p ≤ 0.034). CONCLUSION: Good reproducibility of global and segmental E(CC) measurements using cine DENSE before and after contrast injection is achievable at 3T.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。