Synthetic multi-contrast late gadolinium enhancement imaging using post-contrast magnetic resonance fingerprinting

利用对比后磁共振指纹图谱进行合成多对比度延迟钆增强成像

阅读:1

Abstract

Late gadolinium enhancement (LGE) MRI is the non-invasive reference standard for identifying myocardial scar and fibrosis but has limitations, including difficulty delineating subendocardial scar and operator dependence on image quality. The purpose of this work is to assess the feasibility of generating multi-contrast synthetic LGE images from post-contrast T(1) and T(2) maps acquired using magnetic resonance fingerprinting (MRF). Fifteen consecutive patients with a history of prior ischemic cardiomyopathy (12 men; mean age 63  ± 13 years) were prospectively scanned at 1.5 T between Oct 2020 and May 2021 using conventional LGE and MRF after injection of gadolinium contrast. Three classes of synthetic LGE images were derived from MRF post-contrast T(1) and T(2) maps: bright-blood phase-sensitive inversion recovery (PSIR), black- and gray-blood T(2) -prepared PSIR (T(2) -PSIR), and a novel "tissue-optimized" image to enhance differentiation among scar, viable myocardium, and blood. Image quality was assessed on a 1-5 Likert scale by two cardiologists, and contrast was quantified as the mean absolute difference (MAD) in pixel intensities between two tissues, with different methods compared using Kruskal-Wallis with Bonferroni post hoc tests. Per-patient and per-segment scar detection rates were evaluated using conventional LGE images as reference. Image quality scores were highest for synthetic PSIR (4.0) and reference images (3.8), followed by synthetic tissue-optimized (3.3), gray-blood T(2) -PSIR (3.0), and black-blood T(2) -PSIR (2.6). Among synthetic images, PSIR yielded the highest myocardium/scar contrast (MAD = 0.42) but the lowest blood/scar contrast (MAD = 0.05), and vice versa for T(2) -PSIR, while tissue-optimized images achieved a balance among all tissues (myocardium/scar MAD = 0.16, blood/scar MAD = 0.26, myocardium/blood MAD = 0.10). Based on reference mid-ventricular LGE scans, 13/15 patients had myocardial scar. The per-patient sensitivity/accuracy for synthetic images were the following: PSIR, 85/87%; black-blood T(2) -PSIR, 62/53%; gray-blood T(2) -PSIR, 100/93%; tissue optimized, 100/93%. Synthetic multi-contrast LGE images can be generated from post-contrast MRF data without additional scan time, with initial feasibility shown in ischemic cardiomyopathy patients.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。