Noninvasive Reconstruction of Transmural Transmembrane Potential With Simultaneous Estimation of Prior Model Error

无创重建跨膜电位并同时估计先验模型误差

阅读:2

Abstract

To reconstruct electrical activity in the heart from body-surface electrocardiograms (ECGs) is an ill-posed inverse problem. Electrophysiological models have been found effective in regularizing these inverse problems by incorporating a priori knowledge about how the electrical potential in the heart propagates over time. However, these models suffer from model errors arising from, for example, parameters associated with tissue properties and the earliest sites of excitation. We present a Bayesian approach to simultaneously estimate transmembrane potential (TMP) signals and prior model errors, exploiting sparsity of the error in the gradient domain in the form of a novel sparse prior based on variational lower bound of the generalized Gaussian distribution. In synthetic and real-data experiments, we demonstrate the improvement of accuracy in TMP reconstruction brought by simultaneous model error estimation. We further provide theoretical and empirical justifications for the change of performances in the presented method at the presence of different model errors.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。