Comparison of Absolute Dose Achievable Between Helical Tomotherapy and RapidArc in Total Dura Mater Irradiation for Child Cancer

儿童癌症全硬脑膜照射中螺旋断层放射治疗与RapidArc放射治疗可达到的绝对剂量比较

阅读:1

Abstract

Background and Purpose: In this study, the absolute dose achievable between helical tomotherapy (HT) plans and RapidArc (RA) plans for total dura mater irradiation (TDMI) was compared. Materials and methods: A planning study was conducted on nine children's case datasets with dura mater metastasis of neuroblastoma. The target included the entire calvarium and skull base and formed a closed volume with a certain thickness around the brain. HT and RA plans with four coplanar full arcs (RA4) with half-field technique were generated for the comparison of absolute dose achievable. In total, 30.6 Gy was prescribed as D(95%) (ie, dose to 95% of PTV volume). Results: In the dosimetric comparison between the two modalities, HT provided more homogenous dose distribution than RA4 (mean HI(5-95%): 1.046 vs 1.088, P < .001). The V(107%) and D(2Gy) of PTV in HT versus RA4 were 3.06% versus 30.47% and 32.59 Gy versus 33.45 Gy, respectively. HT reduced the D(mean) and V(5Gy) of the brain, brainstem, and hippocampus by 25%-48% and 27%-56% compared with RA4, respectively. Conclusion: Both techniques could provide sufficient coverage for targets, but HT offered more homogenous dose to PTV and lower dose to the central region of the brain involving the brainstem and hippocampus. RA4 could be completed in a shorter time with lower MUs, but with relatively higher dose to the brain or hippocampus. In terms of dosimetry, HT may improve long-term cognitive decline in these young pediatric patients with TDMI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。