Oxidized Zirconium Total Knee Arthroplasty Implant Failure in a Patient With Knee Instability

氧化锆全膝关节置换术植入物在膝关节不稳患者中发生失效

阅读:1

Abstract

Oxidized zirconium was introduced as an alternative bearing surface to decrease polyethylene wear and reduce aseptic mechanical failure of hip and knee arthroplasties. Oxidized zirconium combines the strength of a metal with wear properties of ceramic, proposing increased survivorship of implant components, and possible decreased rate of revision. Despite a harder surface than cobalt-chromium, the substrate of zirconium is a softer metal. Although uncommon, prior reports have described accelerated wear and severe metallosis after femoral head dislocation in oxidized zirconium total hip arthroplasty; however, this has not been described in total knee arthroplasty. We report a case of an oxidized zirconium total knee arthroplasty failure in a patient with knee instability. This is the first report of catastrophic failure of an oxidized zirconium total knee arthroplasty implant.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。