A Five-Year Comparative Functional and Clinical Evaluation of Two Contemporary Cruciate-Retaining Knee Implants

两种当代保留后交叉韧带膝关节假体的五年比较功能和临床评估

阅读:1

Abstract

BACKGROUND: The purpose of our study was to compare 2 commonly used highly successful cruciate-retaining knee designs on the basis of patient-reported outcome measures (PROMs), range of motion (ROM), and anterior knee pain (AKP) at a minimum follow-up of 5 years. METHODS: A cohort of 65 patients underwent unilateral total knee arthroplasty, from January 2013 to December 2013, using NexGen Cruciate Retaining (Zimmer Biomet, Warsaw, IN), a nonmorphogenic knee (NMK) system. They were subsequently operated upon for the contralateral knee using Persona Cruciate Retaining (Zimmer Biomet, Warsaw, IN), a morphogenic knee (MK) system between January 2014 and June 2014. Of the 65 patients, 63 participated in this study. All the patients were compared preoperatively and postoperatively on the basis of PROMs, ROM, and AKP. RESULTS: On the basis of PROMs, ROM, and AKP, there was a statistically significant difference between the 2 groups favoring the MK group, with an ROM of 126.14° in the MK group as compared with 120.76° in the NMK group and P value of <.01. CONCLUSIONS: PROMs, ROM, and AKP improved significantly over time after total knee arthroplasty using both MK and NMK implants; however, the outcomes of the former were better than those of the latter, although this difference was not clinically significant.