Patient-Reported Outcomes and Knee Mechanics Correlate With Patellofemoral Deep Cartilage UTE-T2* 2 Years After Anterior Cruciate Ligament Reconstruction

患者报告结果和膝关节力学与前交叉韧带重建术后2年髌股关节深层软骨UTE-T2*值相关

阅读:2

Abstract

BACKGROUND: Patellofemoral joint degeneration and dysfunction after anterior cruciate ligament reconstruction (ACLR) are increasingly recognized as contributors to poor clinical outcomes. PURPOSE: To determine if greater deep cartilage matrix disruption at 2 years after ACLR, as assessed by elevated patellofemoral magnetic resonance imaging (MRI) ultrashort echo time-enhanced T2* (UTE-T2*), is correlated with (1) worse patient-reported knee function and pain and (2) gait metrics related to patellofemoral tracking and loading, such as greater external rotation of the tibia at heel strike, reduced knee flexion moment (as a surrogate of quadriceps function), and greater knee flexion angle at heel strike. STUDY DESIGN: Cross-sectional study; Level of evidence, 3. METHODS: MRI UTE-T2* relaxation times in patellar and trochlear deep cartilage were compared with patient-reported outcomes and ambulatory gait metrics in 60 patients with ACLR at 2 years after reconstruction. ACLR gait metrics were compared with those of 60 uninjured reference patients matched by age, body mass index, and sex. ACLR UTE-T2* values were compared with those of 20 uninjured reference patients. RESULTS: Higher trochlear UTE-T2* values were associated with worse Knee injury and Osteoarthritis Outcome Scores (KOOS) Sport/Recreation subscale scores (rho = -0.32; P = .015), and showed a trend for association with worse KOOS Pain subscale scores (rho = -0.26; P = .045). At 2 years after ACLR, greater external rotation of the tibia at heel strike was associated with higher patellar UTE-T2* values (R = 0.40; P = .002); greater knee flexion angle at heel strike was associated with higher trochlear UTE-T2* values (rho = 0.39; P = .002); and greater knee flexion moment showed a trend for association with higher trochlear UTE-T2* values (rho = 0.30; P = .019). Patellar cartilage UTE-T2* values, knee flexion angle at heel strike, and external rotation of the tibia at heel strike were all elevated in ACLR knees as compared with reference knees (P = .029, .001, and .044, respectively). CONCLUSION: Patellofemoral deep cartilage matrix disruption, as assessed by MRI UTE-T2*, was associated with reduced sports and recreational function and with gait metrics reflective of altered patellofemoral loading. As such, the findings provide new mechanistic information important to improving clinical outcomes related to patellofemoral dysfunction after ACLR.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。