Safety and Efficacy of the Amplatzer Septal Occluder: A Systematic Review and Meta-Analysis

Amplatzer房间隔封堵器的安全性和有效性:系统评价和荟萃分析

阅读:1

Abstract

OBJECTIVES: To assess the safety and efficacy of the Amplatzer Septal Occluder in the closure of secundum type atrial septal defects. BACKGROUND: The Amplatzer Septal Occluder (ASO; Abbott, St. Paul, MN) is an FDA-approved device for percutaneous closure of secundum type atrial septal defects (ASD). Previous small cohort trials have shown a favorable safety and technical efficacy profile. METHODS: We conducted a systemic review and meta-analysis of all prospective case series and controlled trials that evaluated the ASO's safety and implant efficacy. The primary endpoint was the technical success rate of implantations. Secondary outcomes included proportions of arrhythmias and embolism specific-adverse events. RESULTS: We included a total of 12 studies with 2972 patients. The ratio of device implantation was 2:1 by sex [female: male]. Pooled technical success rate of implantation was 98% (95% CI: 0.968-0.990, P < 0.01). The cumulative adverse event rate was 5.1% (95% CI: 0.035-0.068, P < 0.01), which included arrhythmia and embolism specific adverse event rates of 1.8% (95% CI: 0.007-0.032, P < 0.01) and 0.7% (95% CI: 0.002-0.013, P < 0.01), respectively. Sensitivity analysis did not significantly affect pooled outcomes for success rate and adverse events; both forest plot and Begg's and Egger's regression tests supported symmetricity. CONCLUSION: A high likelihood of technical success can be expected when implanting the ASO in secundum type ASDs. Adverse event rates are expected for one in twenty patients, and thus, our results support the safe use of ASO in secundum type ASDs closure. CONDENSED ABSTRACT: The AMPLATZER Septal Occluder is an FDA-approved device for percutaneous closure of secundum type atrial septal defects (ASD). We conducted a systemic review and meta-analysis of all prospective case series and controlled trials that evaluated the ASO's safety and implant efficacy. We included a total of 12 studies with 2972 patients. Pooled technical success rate of implantation was 98% (P < 0.01). The cumulative adverse event rate was 5.1% (P < 0.01), 1.8% (P < 0.01) rate of arrhythmias, and 0.7% (P < 0.01) rate of embolisms. A high likelihood of technical success can be expected with a low rate of adverse events.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。