Novel sizing role of 3D transesophageal echocardiography in a novel left atrial appendage clip device for patients undergoing video-assisted atrial fibrillation ablation: a cohort study

三维经食道超声心动图在新型左心耳夹装置尺寸测量中的新作用:一项队列研究

阅读:1

Abstract

BACKGROUND: Three-dimensional (3D) transesophageal echocardiography (TEE) has been successfully used in the sizing of left atrial appendage (LAA) occlusion devices, but its use has not yet been studied in LAA clip devices. We sought to develop and validate the novel use of 3D-TEE sizing in a novel LAA clip device for atrial fibrillation (AF) patients undergoing video-assisted thoracic surgery (VATS) ablation. METHODS: Consecutive patients with isolated AF undergoing LAA clipping or excision during VATS ablation were included in the study between June 2021 and September 2022 at Fuwai Hospital. The patients underwent 3D-TEE examinations preoperatively and postoperatively. The VATS length, LAA clip effective length, and LAA excision margin length were recorded. A correlation analysis, intraclass correlation coefficient (ICC) analysis, and Bland-Altman plot analysis were conducted to examine the TEE parameters, VATS length, LAA clip effective length, and LAA excision margin length. RESULTS: In total, 26 AF patients undergoing LAA clipping and 15 undergoing LAA excision were included in the study. In the LAA clipping group, in which the Atriclip size served as the control, the 3D-TEE with volumetric measurement (the perimeter-derived maximum orifice diameter) (R=0.938; ICC =0.934; Bland-Altman plot variability, 3.85%) showed the best sizing efficacy for the LAA clip device among the 3D-TEE with multiplanar reformatting sizing (the perimeter-derived maximum orifice diameter) (R=0.808; ICC =0.772; Bland-Altman plot variability, 3.85%), VATS sizing (R=0.851; ICC =0.756; Bland-Altman plot variability, 11.54%), and VATS plus 0.5-cm sizing (R=0.851; ICC =0.775; Bland-Altman plot variability, 11.54%) measurements (all P<0.001). In addition, for the distribution of matched sizing in the LAA clip group, 3D-TEE with volumetric measurement sizing (20/26) had a higher proportion than 3D-TEE with multiplanar reformatting sizing (11/26, P=0.011), VATS sizing (9/26, P=0.002), and VATS plus 0.5-cm sizing (14/26, P=0.08). Using the LAA excision margin length as the control, the mean difference in the LAA diameter was 1.17 cm [95% confidence interval (CI): 0.71-1.62 cm , P<0.001] in the maximum orifice diameter of two-dimensional-TEE, 0.15 cm (95% CI: -0.32 to 0.61 cm , P=0.523) in the perimeter-derived 3D multiplanar reformatting (the maximum orifice diameter), and 0.03 cm (95% CI: -0.47 to 0.53, P=0.901) in the perimeter-derived 3D volumetric (3DV) measurement (the maximum orifice diameter), and the related Pearson correlation coefficients for these modalities were 0.760 (P=0.001), 0.843 (P<0.001), and 0.963 (P<0.001), respectively. CONCLUSIONS: Our study showed that 3D-TEE might be employed in the sizing of a novel LAA clip device using the VATS approach in patients with AF. The 3DV measurement (the perimeter-derived maximum orifice diameter) was superior to the VATS measurement. These findings might also apply to LAA VATS excision patients with AF.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。