Real-Life Performance and Clinical Outcomes of Portico Transcatheter Aortic Valve with FlexNav Delivery System: One-Year Data from a Single-Center Experience

Portico经导管主动脉瓣置换术联合FlexNav输送系统在真实世界中的性能和临床结果:来自单中心的一年数据

阅读:1

Abstract

Significant progress has been made in both valves and delivery systems (DSs) for transcatheter aortic valve replacement (TAVR) procedures. We aimed to present one-year real-life data regarding TAVR procedures using Portico transcatheter heart valves (THVs) with new-generation, low-profile FlexNav DSs. This retrospective, single-center study enrolled 169 consecutive patients (mean age: 75.8 years, 68% females) with severe aortic stenosis undergoing TAVR with Portico THVs and FlexNav DSs between 2020 and 2021. We evaluated safety and efficacy outcomes, following the VARC-3 consensus, periprocedurally and at 30 days and 1 year. Procedural success was observed in 95.9% of cases, and no procedural mortality occurred. At 30 days, the rates of all-cause mortality, cardiovascular mortality, and neurological events were 4.7%, 3.6%, and 3.0%, respectively. Additionally, major vascular complications, acute kidney injury, and bleeding were recorded at rates of 11.2%, 14.8%, and 7.7%, respectively. The 1-year data showed all-cause mortality, cardiovascular mortality, and neurological event rates of 10.7%, 8.3%, and 7.7%, respectively. The moderate paravalvular leak and permanent pacemaker rates at 1 year were 2.6% and 12.2%, respectively. This real-life data provided evidence of positive outcomes and high technical success with Portico THVs and FlexNav DSs. Furthermore, we found low rates of mortality and neurological events, with satisfactory hemodynamic and functional results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。