The use of ultrasound to measure muscle depth and area in postmortem Holstein dairy calves

利用超声波测量荷斯坦奶牛犊死后肌肉的深度和面积

阅读:1

Abstract

Monitoring growth of neonatal dairy calves is a useful management tool to assist producers in achieving goals for reproduction and performance. The goal of this study was to examine ultrasound as an in vivo tool to quantify longissimus dorsi muscle (ribeye) linear depth and extensor carpi radialis (ECR) and semitendinosus (ST) muscle cross-sectional areas in postmortem preweaned Holstein calves. Postmortem preweaned calves (n = 137, age 13.1 d ± 15.5 SD, body weight 36.5 kg ± 7.2 SD) were obtained from two California calf ranches between April and July 2013. Two operators collected ultrasound images of the ribeye, ECR, and ST muscles using an Aloka 500V equipped with a 5-cm 7.5-MHz linear transducer. Ultrasound ribeye linear depth and ECR and ST cross-sectional areas were calculated using the Ultrasound Image Capture System. Ultrasound measurements were compared to dissected (carcass) measures. Carcass ribeye linear depth was estimated using a ruler. Dissected ECR and ST muscle cross-sectional areas were estimated by tracing muscle cross sections onto transparency paper and then photocopying, cutting out, and weighing individual paper muscle tracings. Weights of the tracings were then converted to areas using the known area of a standard 8.5 × 11 inch paper. Data were analyzed by regressing carcass estimates on observed ultrasound measurements. The coefficient of determination (R (2)) indicated that ultrasound measurements were most closely associated with carcass measurements for the ST muscle (R (2) = 0.60, 0.62 for operator 1 and 2, respectively) when compared to the ribeye and ECR muscles (R (2) = 0.27, 0.41 for ribeye and 0.43, 0.32 for ECR for operator 1 and 2, respectively). The mean bias showed consistent underestimation by the ultrasound measurements when predicting carcass measurements for all three muscles and for both operators (ribeye bias = 0.15, 0.40; ECR bias = 0.95, 1.15; and ST bias = 0.73, 0.27 for operator 1 and 2, respectively). Operator contributed significantly in explaining a proportion of the variation in the regression equation for the ST muscle only, whereas calf body weight contributed significantly in explaining a proportion of the variation in the regression equation for all three muscles. The results of this study demonstrated that ultrasound measurements of the ST were the most accurate for quantifying the cross-sectional area when compared to both the ECR and ribeye in postmortem Holstein calves.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。