Correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes

青光眼、高眼压和正常眼中眼灌注压与眼脉搏幅度的相关性

阅读:1

Abstract

BACKGROUND: The purpose of this study was to investigate the correlation between ocular perfusion pressure and ocular pulse amplitude in glaucoma, ocular hypertension, and normal eyes. METHODS: Ninety eyes from 90 patients were included. Thirty patients had been recently diagnosed with glaucoma and had no previous history of treatment for ocular hypotension, 30 had elevated intraocular pressure (IOP) without evidence of glaucoma, and 30 had normal IOP (<21 mmHg) with no detectable glaucomatous damage. Goldmann applanation tonometry (GAT), dynamic contour tonometry (DCT), blood pressure measurement, pachymetry, Humphrey visual field, and routine ophthalmic examination was performed in each patient. Ocular perfusion pressure was calculated as the difference between mean arterial pressure and IOP. The ocular pulse amplitude was given by DCT. The Pearson correlation coefficient was used to compare the glaucomatous and ocular hypertensive groups, and comparisons with the normal IOP group were done using the Spearman's rank correlation coefficient. RESULTS: Mean IOP by DCT was 22.7 ± 4.3 mmHg in the glaucoma group, 22.3 ± 2.8 mmHg in the ocular hypertension group, and 14.3 ± 1.6 mmHg in the control group. Mean IOP by GAT was 19.0 ± 5.1 mmHg for glaucoma, 22.4 ± 2.1 mmHg for ocular hypertension, and 12.9 ± 2.2 mmHg for controls. Mean ocular pulse amplitude was 3.4 ± 1.2 mmHg in the glaucoma group, 3.5 ± 1.2 mmHg in the ocular hypertension group, and 2.6 ± 0.9 mmHg in the control group. Mean ocular perfusion pressure was 46.3 ± 7.9 mmHg in the glaucoma group, 46.3 ± 7.9 mmHg in the ocular hypertension group, and 50.2 ± 7.0 mmHg in controls. No significant correlation between ocular perfusion pressure and ocular pulse amplitude was found in any of the groups (P = 0.865 and r = -0.032, P = 0.403 and r = -0.156, P = 0.082 and ρ = -0.307 for glaucoma, ocular hypertension, and normal eyes, respectively). CONCLUSION: There is no significant correlation between ocular perfusion pressure and ocular pulse amplitude values in glaucoma, ocular hypertension, or normal eyes. IOP values measured by GAT correlate with those measured by DCT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。