Dark-blood late gadolinium enhancement without additional magnetization preparation

暗血后期钆增强,无需额外磁化准备

阅读:2

Abstract

BACKGROUND: This study evaluates a novel dark-blood late gadolinium enhancement (LGE) cardiovascular magnetic resonance imaging (CMR) method, without using additional magnetization preparation, and compares it to conventional bright-blood LGE, for the detection of ischaemic myocardial scar. LGE is able to clearly depict myocardial infarction and macroscopic scarring from viable myocardium. However, due to the bright signal of adjacent left ventricular blood, the apparent volume of scar tissue can be significantly reduced, or even completely obscured. In addition, blood pool signal can mimic scar tissue and lead to false positive observations. Simply nulling the blood magnetization by choosing shorter inversion times, leads to a negative viable myocardium signal that appears equally as bright as scar due to the magnitude image reconstruction. However, by combining blood magnetization nulling with the extended grayscale range of phase-sensitive inversion-recovery (PSIR), a darker blood signal can be achieved whilst a dark myocardium and bright scar signal is preserved. METHODS: LGE was performed in nine male patients (63 ± 11y) using a PSIR pulse sequence, with both conventional viable myocardium nulling and left ventricular blood nulling, in a randomized order. Regions of interest were drawn in the left ventricular blood, viable myocardium, and scar tissue, to assess contrast-to-noise ratios. Maximum scar transmurality, scar size, circumferential scar angle, and a confidence score for scar detection and maximum transmurality were also assessed. Bloch simulations were performed to simulate the magnetization levels of the left ventricular blood, viable myocardium, and scar tissue. RESULTS: Average scar-to-blood contrast was significantly (p < 0.001) increased by 99% when nulling left ventricular blood instead of viable myocardium, while scar-to-myocardium contrast was maintained. Nulling left ventricular blood also led to significantly (p = 0.038) higher expert confidence in scar detection and maximum transmurality. No significant changes were found in scar transmurality (p = 0.317), normalized scar size (p = 0.054), and circumferential scar angle (p = 0.117). CONCLUSIONS: Nulling left ventricular blood magnetization for PSIR LGE leads to improved scar-to-blood contrast and increased expert confidence in scar detection and scar transmurality. As no additional magnetization preparation is used, clinical application on current MR systems is readily available without the need for extensive optimizations, software modifications, and/or additional training.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。