Comparison of blood pressure measurements using an automated blood pressure device in community pharmacies and family physicians' offices: a randomized controlled trial

社区药房和家庭医生诊所使用自动血压计测量血压的比较:一项随机对照试验

阅读:1

Abstract

BACKGROUND: Accurate measurement of blood pressure is the foundation of appropriate diagnosis, treatment and ongoing management of hypertension. The use of automated blood pressure devices in community settings such as pharmacies provide opportunities for additional blood pressure measurement; however, it is important to ensure that these measurements are comparable to those taken in physicians' offices using the same devices. We conducted a randomized controlled trial to assess whether blood pressure readings assessed by use of an automated device differed according to the setting, specifically in community pharmacies and family physicians' offices. METHODS: We included adults aged 65 years and older who did not live in long-term care facilities or in hospital. The trial was administered by volunteer peer health educators, family physicians and pharmacists in 2 midsized communities in Ontario from April to September 2010. The 5 participating family physicians mailed invitations to their eligible patients. Those who gave informed consent were randomly allocated to 1 of 2 assessment sequences: group A had their blood pressure measured at their physician's office, then at a pharmacy, then again at their physician's office; those in group B had their blood pressure measured at a pharmacy, then at their physician's office, then again at a pharmacy. An automated blood pressure device (BpTRU) was used in both settings. We calculated the differences in mean systolic and diastolic blood pressure, and we compared the readings at both settings and by sequence of assessment. RESULTS: In total, 275 adults completed the trial (mean age 75.9 yr, 49.5% male, 46.9% with a self-reported diagnosis of hypertension). There were no statistically significant differences in systolic or diastolic blood pressure measurements associated with the sequence of assessment or the setting. There was a significant difference in the overall mean systolic blood pressure between the 2 assessment sequences (group A 122.0 v. group B 127.8 mm Hg, p < 0.001). INTERPRETATION: Automated devices used in pharmacies to measure blood pressure provide accurate and valid information that can be used in the diagnosis and management of hypertension among older adults in the community. TRIAL REGISTRATION: www.controlled-trials.com, no. ISRCTN91799042.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。