Dedicated removal of immunoglobulin (Ig)A, IgM, and Factor (F)XI/activated FXI from human plasma IgG

专门从人血浆 IgG 中去除免疫球蛋白 (Ig)A、IgM 和因子 (F)XI/活化 FXI

阅读:7
作者:Yu-Wen Wu, Jérôme Champagne, Magali Toueille, René Gantier, Thierry Burnouf

Background

Adverse events can be associated with treating critically ill patients with immunoglobulin (Ig)G. Some adverse events are due to contaminants like IgA and activated Factor (F)XI. Therefore, new purification strategies are needed for dedicated removal of these contaminants without impairing IgG recovery. Study design and

Conclusions

Combining S HyperCel and HyperCel STAR AX extensively removed IgA and IgM, with good IgG recovery. Mustang® S membranes can be used for dedicated removal of FXI.

Methods

An immunoglobulin fraction containing IgG, IgM, and IgA was prepared by caprylic acid precipitation of cryoprecipitate-poor plasma. The capacities of the cation exchangers (S HyperCel and CM Ceramic HyperD F) and anion exchangers (HyperCel STAR AX and Q HyperCel) to remove IgA, IgM, and spiked FXI were tested following a design of experiment approach using microplates and chromatographic column scale-up. FXI removal was also evaluated using Mustang S chromatographic membranes. IgG/IgG subclasses, IgA, IgM, and FXI were assessed by enzyme-linked immunosorbent assay, and caprylic acid, by gas chromatography.

Results

Extensive removal of IgA and IgM, but not FXI, was achieved by a two-step chromatographic process combining S HyperCel used in the IgG binding and elution mode and HyperCel STAR AX used in the IgG flow-through mode, providing high IgG and IgG subclass recovery (>85%), high purity (>99.5%), and efficient removal of IgA (<0.5%) and IgM (undetectable). Twenty-six-fold FXI removal was achieved by processing the resulting purified IgG fraction through Mustang S cation-exchanger membranes at pH 6.0 and 12.7 mS/cm. Caprylic acid was removed by S HyperCel. Conclusions: Combining S HyperCel and HyperCel STAR AX extensively removed IgA and IgM, with good IgG recovery. Mustang® S membranes can be used for dedicated removal of FXI.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。