Assessing the validity of Prostate Imaging Reporting and Data System version 2 (PI-RADS v2) scoring system in diagnosis of peripheral zone prostate cancer

评估前列腺影像报告和数据系统第2版(PI-RADS v2)评分系统在诊断外周带前列腺癌中的有效性

阅读:1

Abstract

THE PURPOSE: Assessing the accuracy of multi parametric magnetic resonance (mp-MRI) after application of PI-RADS V2 for diagnosis of prostate cancer as comparison to pathological results of trans rectal ultra-sound (TRUS) guided biopsy. PATIENTS AND METHODS: 138 prostatic lesions in 23 patients were retrospectively assessed and analyzed with Trans rectal ultra-sound (TRUS) guided biopsy results. Those patients underwent multi parametric magnetic resonance (mp-MRI) with application of PI-RADS V2 reporting system. The sensitivity, specificity, validity, negative predictive value and positive predictive value were calculated for PI-RADS V2 reporting system compared to biopsy-proven pathological results. RESULTS: 92 out of 138 lesions were positive for Peripheral zone cancer prostate. PI-RADS V2 reporting system proved 88.04% sensitive & 93.4% specific for diagnosis of prostate cancer with negative predictive value & positive predictive value of 100%. CONCLUSION: Our results proved that mp-MRI of prostate using PI-RADS v2 scoring system had high sensitivity and specificity in diagnosis of prostate cancer and PI-RADS V2 scoring system using mp-MRI is recommended as a non-invasive diagnostic tool compared to TRUS guided biopsy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。