Cost-Effectiveness of the FreeStyle Libre(®) System Versus Blood Glucose Self-Monitoring in Individuals with Type 2 Diabetes on Insulin Treatment in Sweden

瑞典接受胰岛素治疗的2型糖尿病患者中,FreeStyle Libre®系统与血糖自我监测的成本效益比较

阅读:1

Abstract

INTRODUCTION: Frequent glucose monitoring is essential to obtain glucose control. This is done by periodic self-monitoring of blood glucose (SMBG) using finger-prick testing, or by using continuous glucose monitoring devices, wherein a sensor records interstitial glucose data automatically. This study assessed the cost-effectiveness of using the FreeStyle Libre Flash Continuous Glucose Monitoring System (FSL) compared to SMBG in individuals with type 2 diabetes (T2D) treated with insulin from a Swedish societal perspective. METHODS: Cost-effectiveness analysis was conducted using the IQVIA Core Diabetes model v9.5, with demographic and clinical inputs from a real-world study using Swedish National Diabetes Register data. Two cohorts of individuals with T2D were considered based on baseline HbA1C (HbA1c: 8-9% [64-75 mmol/mol]; HbA1c: 9-12% [75-108 mmol/mol]). HbA1c reductions with FSL were - 0.41% (- 4 mmol/mol; SD: 0.94%-10 mmol/mol) and - 1.30% (- 14 mmol/mol; SD: 1.40%-15 mmol/mol) for the two cohorts, respectively. Utilities, treatment costs and diabetes-related complication costs were obtained from published sources. Analyses were conducted over a lifetime horizon, applying annual discounting of 3% on costs and effects. Scenario analyses and probabilistic sensitivity analyses were performed. RESULTS: Individuals with T2D who had a baseline HbA1c of 8-9% (64-75 mmol/mol) and 9-12% (75-108 mmol/mol) and used FSL gained 0.50 and 0.57 quality-adjusted life-years (QALYs), respectively, at an incremental cost of SEK109,957 and SEK82,170 compared to SMBG, generating an incremental cost-utility ratio of SEK219,127 and SEK144,412 per QALY gained. Assuming a willingness-to-pay threshold of SEK300,000 per QALY gained, FSL use was considered cost-effective compared to SMBG for the majority of the individuals in both the lower and higher HbA1c cohorts. The key driver identified was the additional quality-of-life benefit that applied to FSL use. CONCLUSION: The FreeStyle Libre Flash Continuous Glucose Monitoring System is a cost-effective glucose monitoring alternative to SMBG for individuals with T2D in Sweden who are treated with insulin but are not reaching their glycaemic goals.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。