Assessment of Patient Satisfaction with On-Site Point-of-Care Hemoglobin A1c Testing: An Observational Study

评估患者对现场即时糖化血红蛋白A1c检测的满意度:一项观察性研究

阅读:1

Abstract

INTRODUCTION: Poor glycemic control is a serious challenge in successful diabetes management. Given the low adherence and compliance with HbA1c testing frequency and the corresponding delay in the appropriate medication adjustment, point-of-care testing (POCT) for HbA1c provides an opportunity for better control of diabetes and higher patient satisfaction. The data with this regard are limited in Saudi Arabia. Therefore, we aimed to assess the level of patient satisfaction associated with the POCT service implementation for HbA1c and evaluate the differences between the number of requested and conducted HbA1c tests before and after POCT implementation and its effect on glycemic control in Saudi clinical practice. METHODS: We conducted a single-center ambispective descriptive cohort study in Riyadh, Saudi Arabia. This study had two phases: the retrospective phase (January 2017 to December 2017) and the prospective phase (January 2018 to December 2018). Patient satisfaction was assessed using the patient satisfaction questionnaire short form (PSQ-18) and on-site HbA1c point-of-care testing (HbA1c-POCT) satisfaction questionnaire. RESULTS: This study included 75 patients with diabetes (37% type 1, 63% type 2) with a mean age of 44.35 (± 17.97) years. The adherence to physician recommendations for HbA1c testing frequency increased from 24% to 85% (before and after POCT implementation, respectively). High levels of satisfaction across seven dimensions of PSQ-18 (77-88%) were reported towards the provided healthcare service after POCT implementation. Furthermore, a high level of agreement on the statements of the on-site HbA1c-POCT satisfaction questionnaire was also observed. Finally, the mean HbA1c level has significantly improved after POCT implementation compared to the traditional HbA1c laboratory testing before POCT implementation [8.34 ± 0.67 and 8.06 ± 0.62, respectively, p < 0.001). CONCLUSION: HbA1c testing at POCT improved adherence to recommendations for HbA1c testing frequency for better glycemic control and higher patient satisfaction. POCT reduces turnaround time, improves glycemic control, and facilitates the decision-making process. HbA1c measurement with POC devices is recommended to be implemented in diabetes treatment centers. All of the described benefits of POCT come together to make HbA1c testing the most common procedure for diabetes management at the point of care.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。