Measurement Uncertainty Impacts Diagnosis of Diabetes Mellitus: Reliable Minimal Difference of Plasma Glucose Results

测量不确定性影响糖尿病诊断:血浆葡萄糖结果的可靠最小差异

阅读:1

Abstract

INTRODUCTION: The diagnosis of diabetes mellitus is based on suitable cut-off values of specific biomarkers, such as the concentration of glucose in plasma. The German Diabetes Association has very recently published a clinical practice guideline on the definition, classification and diagnosis of diabetes mellitus that recommends measurements of plasma glucose concentration have an imprecision defined as a minimal difference (MD) of at a fasting plasma glucose concentration of 7.0 mmol/L. To obtain reliable values for the MD, we investigated long-term and short-term measurement uncertainty. METHODS: The imprecision was determined by two approaches: (1) a long-term dataset with imprecision based on the Guideline of the German Medical Association on Quality Assurance in Medical Laboratory Examinations (Rili-BAEK), in a medical laboratory operating 24/7, using internal quality control (IQC) data for four concentrations during a 10-year period; and (2) a detailed short-term dataset with imprecision assessed by hourly measurements of control materials. These datasets were used to calculate the MD cut-off (MD(cut-off)) as: [Formula: see text]  = 2  [Formula: see text], where SD is the standard deviation and k = 2 represents a confidence level of 95%. RESULTS: The MD(cut-off) of ≤ 0.7 mmol/L at a fasting plasma glucose concentration of 7.0 mmol/L (MD(cut-off 7.0)) for the long-term and the short-term approaches were 0.44 and 0.40 mmol/L, respectively. The MD(cut-off 7.0) from both approaches was therefore below the recommended value of 0.7 mmol/L. It was noted that the variability in performance within and between instruments can be covered by reporting the long-term MD(cut-off 7.0) across all connected instruments. In this study, stable results for the MD(cut-off 7.0) were obtained after 1 year. CONCLUSION: Imprecision as measured by IQC data is remarkably stable over many years of operation. Current imprecision assessment usually focuses on only single instruments, whereas clinicians perceive the measurement as the result of the combined analytical performance of all instruments used for a certain assay. In the clinical setting, the MD may be a more useful measure of imprecision, and we suggest deriving the MD(cut-off) combined from all instruments and control cycles that are used in the patient care setting for a given analyte.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。