Comparison of Partial Thickness and Full Thickness Tragal Cartilage Graft During Modified Cartilage Shield Tympanoplasty for Type I Procedures

改良软骨盾鼓室成形术中部分厚度与全厚度耳屏软骨移植的比较(I型手术)

阅读:1

Abstract

To compare the results, in terms of graft uptake and hearing improvement, of modified cartilage shield technique of tympanoplasty using either partial thickness tragal cartilage or full thickness tragal cartilage for type I procedures. 35 patients were included in group A where a partial thickness tragal cartilage was used and 27 patients included in group B where a full thickness tragal cartilage was used for modified cartilage shield tympanoplasty. Audiometry done at 4 months after surgery and the results compared. The graft take up rate for both these techniques is excellent. There had been no statistically significant difference in hearing gain between these two groups, except at 4,000 Hz, where hearing gain had been more in group A than group B with P value being 0.027. The modified cartilage shield tympanoplasty is a good technique for closure of tympanic membrane perforations. Hearing gain is very much similar between thin and thick cartilage groups, except at 4,000 Hz.