Unworn cartilage in total knee arthroplasty strongly deviates from 2 mm: MRI, robotic-assisted and ruler assessment

全膝关节置换术中未磨损软骨的厚度与 2 毫米存在显著偏差:MRI、机器人辅助和标尺评估

阅读:2

Abstract

BACKGROUND: Kinematic alignment (KA) in total knee arthroplasty (TKA) aims to resurface the articular surface of the pre-arthritic knee. One cornerstone of KA TKA and the basis for conventional instrumentation (CI) is a 2 mm cartilage thickness of the healthy distal femur. This study of image-based (CT) robotic-assisted surgery (RAS) TKA determined (1) the difference in measuring cartilage thickness using preoperative MRI, the RAS registration probe and MRI and (2) the percentage of knees with a <1.5 or >2.5 mm thickness of the unworn cartilage. METHODS: Forty-two patients undergoing a TKA using an image-based RAS were included. Preoperative long-leg radiographs provided the limb phenotype. The two zones of interest for cartilage thickness were the distal unworn (DU) and posterior unworn (PU) condyle. The preoperative MRI provided cartilage thickness values for both zones. Intraoperatively, the surgeon identified the zones without cartilage wear (healthy cartilage) and measured the distance between the cartilage and bone with the RAS registration probe. After resecting the condyles, a ruler was provided to measure the cartilage thickness reference. RESULTS: Mean patient age was 68.2 ± 4.1 years, and gender was evenly distributed. According to the phenotype classification, there were 8 NEU(HKA)0°, 13 VAR(HKA)3°, 9 VAR(HKA)6°, 5 VAR(HKA)9°, 4 VAL(HKA)3°, 2 VAL(HKA)6° and 1 VAL(HKA)9° patient. The difference between measurement techniques was not statistically significant for both zones (DU p = 0.960, PU p = 0.267). In seven patients (16.7%), the DU cartilage thickness was >2.5 mm measured with any of the three techniques, and up to 50% of patients had unworn cartilage thickness <1.5 mm, depending on the zone and measurement technique. CONCLUSION: There is a significant variation of unworn cartilage thickness from the assumed 2 mm, with a significant proportion (up to 67.7%) having >2.5 or <1.5 mm. If KA is applied, additional preoperative or intraoperative measurements might provide valuable information to avoid the risk of femoral component malposition. LEVEL OF EVIDENCE: Level II, diagnostic study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。