Cartilage-on-cartilage versus metal-on-cartilage impact characteristics and responses

软骨对软骨与金属对软骨的冲击特性和反应

阅读:1

Abstract

A common in vitro model for studying acute mechanical damage in cartilage is to impact an isolated osteochondral or cartilage specimen with a metallic impactor. The mechanics of a cartilage-on-cartilage (COC) impact, as encountered in vivo, are likely different than those of a metal-on-cartilage (MOC) impact. The hypothesis of this study was that impacted in vitro COC and MOC specimens would differ in their impact behavior, mechanical properties, chondrocyte viability, cell metabolism, and histologic structural damage. Osteochondral specimens were impacted with either an osteochondral plug or a metallic cylinder at the same delivered impact energy per unit area, and processed after 14 days in culture. The COC impacts resulted in about half of the impact maximum stress and a quarter of the impact maximum stress rate of change, as compared to the MOC impacts. The impacted COC specimens had smaller changes in mechanical properties, smaller decreases in chondrocyte viability, higher total proteoglycan content, and less histologic structural damage, as compared to the impacted MOC specimens. If MOC impact conditions are to be used for modeling of articular injuries and post-traumatic osteoarthritis, the differences between COC and MOC impacts must be kept in mind.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。