Assessment of mechanical properties of articular cartilage with quantitative three-dimensional ultrashort echo time (UTE) cones magnetic resonance imaging

利用定量三维超短回波时间(UTE)锥形磁共振成像评估关节软骨的力学性能

阅读:1

Abstract

Conventional magnetic resonance imaging (MRI) is not capable of detecting signal from the deep cartilage due to its short transverse relaxation time (T2). Moreover, several quantitative MRI techniques are significantly influenced by the magic angle effect. The combinations of ultrashort echo time (UTE) MRI with magnetization transfer (UTE-MT) and Adiabatic T(1ρ) (UTE-AdiabT(1ρ)) imaging allow magic angle-insensitive assessments of all regions of articular cartilage. The purpose of this study was to investigate the correlations between quantitative three-dimensional UTE MRI biomarkers and mechanical properties of human tibiofemoral cartilage specimens. In total, 40 human tibiofemoral cartilage specimens were harvested from three male and four female donors (64 ± 18 years old). Cartilage samples were scanned using a series of quantitative 3D UTE Cones T(2)* (UTE-T(2)*), T(1) (UTE-T(1)), UTE-AdiabT(1ρ), and UTE-MT sequences in a standard knee coil on a clinical 3T scanner. UTE-MT data were acquired with a series of MT powers and frequency offsets to calculate magnetization transfer ratio (MTR), as well as macromolecular fraction (MMF) and macromolecular T(2) (T(2)mm) through modeling. Cartilage stiffness and Hayes elastic modulus were measured using indentation tests. Correlations of 3D UTE Cones MRI measurements in the superficial layer, deep layer, and global regions of interest (ROIs) with mechanical properties were investigated. Cartilage mechanical properties demonstrated highest correlations with UTE measures of the superficial layer of cartilage. AdiabT(1ρ), MTR, and MMF in superficial layer ROIs showed significant correlations with Hayes elastic modulus (p < 0.05, R = -0.54, 0.49, and 0.66, respectively). These UTE measures in global ROIs showed significant, though slightly lower, correlations with Hayes elastic modulus (p < 0.05, R = -0.37, 0.52, and 0.60, respectively). Correlations between other UTE MRI measurements (T(2)*, T(1), and T(2)mm) and mechanical properties were non-significant. The 3D UTE-AdiabT(1ρ) and UTE-MT sequences were highlighted as promising surrogates for non-invasive assessment of cartilage mechanical properties. MMF from UTE-MT modeling showed the highest correlations with cartilage mechanics.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。