Five-minute knee MRI for simultaneous morphometry and T(2) relaxometry of cartilage and meniscus and for semiquantitative radiological assessment using double-echo in steady-state at 3T

采用3T双回波稳态序列,进行5分钟膝关节MRI扫描,同时测量软骨和半月板的形态和T2弛豫时间,并进行半定量放射学评估。

阅读:1

Abstract

BACKGROUND: Biomarkers for assessing osteoarthritis activity necessitate multiple MRI sequences with long acquisition times. PURPOSE: To perform 5-minute simultaneous morphometry (thickness/volume measurements) and T(2) relaxometry of both cartilage and meniscus, and semiquantitative MRI Osteoarthritis Knee Scoring (MOAKS). STUDY TYPE: Prospective. SUBJECTS: Fifteen healthy volunteers for morphometry and T(2) measurements, and 15 patients (five each Kellgren-Lawrence grades 0/2/3) for MOAKS assessment. FIELD STRENGTH/SEQUENCE: A 5-minute double-echo steady-state (DESS) sequence was evaluated for generating quantitative and semiquantitative osteoarthritis biomarkers at 3T. ASSESSMENT: Flip angle simulations evaluated tissue signals and sensitivity of T(2) measurements. Morphometry and T(2) reproducibility was compared against morphometry-optimized and relaxometry-optimized sequences. Repeatability was assessed by scanning five volunteers twice. MOAKS reproducibility was compared to MOAKS derived from a clinical knee MRI protocol by two readers. STATISTICAL TESTS: Coefficients of variation (CVs), concordance confidence intervals (CCI), and Wilcoxon signed-rank tests compared morphometry and relaxometry measurements with their reference standards. DESS MOAKS positive percent agreement (PPA), negative percentage agreement (NPA), and interreader agreement was calculated using the clinical protocol as a reference. Biomarker variations between Kellgren-Lawrence groups were evaluated using Wilcoxon rank-sum tests. RESULTS: Cartilage thickness (P = 0.65), cartilage T(2) (P = 0.69), and meniscus T(2) (P = 0.06) did not significantly differ from their reference standard (with a 20° DESS flip angle). DESS slightly overestimated meniscus volume (P < 0.001). Accuracy and repeatability CVs were <3.3%, except the meniscus T(2) accuracy (7.6%). DESS MOAKS had substantial interreader agreement and high PPA/NPA values of 87%/90%. Bone marrow lesions and menisci had slightly lower PPAs. Cartilage and meniscus T(2) , and MOAKS (cartilage surface area, osteophytes, cysts, and total score) was higher in Kellgren-Lawrence groups 2 and 3 than group 0 (P < 0.05). DATA CONCLUSION: The 5-minute DESS sequence permits MOAKS assessment for a majority of tissues, along with repeatable and reproducible simultaneous cartilage and meniscus T(2) relaxometry and morphometry measurements. LEVEL OF EVIDENCE: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:1328-1341.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。