A comprehensive testing protocol for macro-scale mechanical characterization of knee articular cartilage with documented experimental repeatability

一套用于膝关节软骨宏观力学表征的综合测试方案,并已记录实验重复性

阅读:1

Abstract

Articular cartilage mechanics has been extensively studied with various approaches and mechanical characterization strategies. However testing protocols can be highly varying and difficult to reproduce, particularly for specimen-specific analyses. Detailed knowledge of testing protocols is important for reliable use in concordant finite element analyses. This study presents a detailed, robust procedure for cartilage testing-with multiple regions and per sample repeatability data. Samples were taken from femur, tibia and patella of a human cadaver knee and tested in unconfined compression, confined compression and uniaxial tension. Each test was repeated three times. The testing protocols provide elastic and time dependent characterization data. Results, for example equilibrium modulus of 0.28 (0.0024) MPa for patella under unconfined compression indicate that variability is well controlled and that protocol(s) presented here can generate repeatable specimen-specific data. As per the authors' knowledge this is the first study to report in-depth uncertainty assessment of the experimental procedures for multi-region knee cartilage characterization.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。