Assessment of the sacroiliac joint in patients with axial spondyloarthritis via three-dimensional ultrashort echo time magnetic resonance imaging

利用三维超短回波时间磁共振成像评估轴性脊柱关节炎患者的骶髂关节

阅读:3

Abstract

BACKGROUND: Bone erosion in the sacroiliac joint (SIJ) is highly specific for the diagnosis of axial spondyloarthritis (axSpA) and may indicate early disease progression. The 3D ultrashort echo time (3D-UTE) technique excels in providing clear contrast between the articular cartilage and the bone cortex interface. Additionally, it is emerging as a promising quantitative tool for detecting early cartilage changes. Therefore, this study aimed to evaluate the diagnostic performance of 3D-UTE sequences in identifying bone erosion in the SIJ of patients with axSpA and to clarify the potential of cartilage T2* values as a quantitative biomarker for axSpA. METHODS: This prospective study employed convenience and consecutive sampling methods to recruit patients diagnosed with axSpA in Peking University Third Hospital who met the Assessment of Spondyloarthritis International Society (ASAS) criteria and also an equal number of healthy volunteers. After providing informed consent, all participants underwent 3D-UTE sequences and conventional T2* mapping of the SIJs. Two radiologists separately interpreted the bone erosion of each SIJ on 3D-UTE sequences. Erosion detection of SIJs via computed tomography (CT) served as the standard of reference. The T2* values of the cartilage were measured and compared, and the diagnostic efficacy of the T2* value for axSpA diagnosis was evaluated. RESULTS: A total of 32 patients and 32 healthy volunteers were included. The 3D-UTE sequence, as separately assessed by two reviewers in terms of its ability to detect erosions, exhibited a notable level of accuracy. For the two reviewers, the respective diagnostic sensitivities were 94.7% and 92.9%, the specificities were 97.4% and 96.5%, positive predictive values were 96.7% and 95.4%, the negative predictive values were 95.9% and 94.5%, the accuracies were 96.2% and 94.9%, and the areas under the curve (AUCs) were 96.1% and 94.7%. For the detection of erosions, the interreader κ value was 0.949. The T2* values of the SIJ cartilage were significantly higher in patients with axSpA than in healthy volunteers. The intraobserver intraclass correlation coefficients (ICCs) for T2* measurements ranged between 80.5% and 82.2%. Meanwhile, the interobserver ICCs for UTE-T2* and gradient echo T2* measurements were 81.5% and 80.8%, respectively. The AUCs of the UTE-T2* values for discriminating patients with axSpA from the healthy volunteers of the two readers were 73.3% and 71.6%, respectively. CONCLUSIONS: 3D-UTE sequences can be used as a reliable morphological imaging technique for detecting bone erosion in the SIJ. Additionally, UTE-T2* values of the cartilage may offer a quantitative method for identifying patients with axSpA.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。