Accuracy measures of 1.5-tesla MRI for the diagnosis of ACL, meniscus and articular knee cartilage damage and characteristics of false negative lesions: a level III prognostic study

1.5特斯拉磁共振成像诊断前交叉韧带、半月板和膝关节软骨损伤的准确性指标及假阴性病变特征:一项III级预后研究

阅读:2

Abstract

BACKGROUND: MRI is the most accurate imaging modality for diagnosing knee pathologies. However, there is uncertainty concerning factors predicting false negative MRI, such as meniscal tear patterns as well as patient factors. The aims of this study were to report 1.5-Tesla MRI accuracy of ACL, meniscus and articular cartilage damage and characterize false negative lesions. METHODS: Two hundred eighteen consecutive knee arthroscopies performed in our institution between 2013 and 2016 and their respective prospectively-collected MRI reports were reviewed. Inclusion criteria were age > 15 years-old, primary arthroscopy, 1.5-Tesla MRI performed at the same institution, and time interval MRI-surgery < 6 months. Exclusion criteria were revision arthroscopy and arthroscopic-assisted fracture fixation or multiligament surgery. Accuracy measures and Kappa coefficients were calculated comparing the MRI diagnosis to the arthroscopic findings. Moreover, the arthroscopic findings of false negative MRI were compared to the findings of true positive MRI using the Fisher-exact test. Pearson correlation was used for testing the correlation between MRI accuracy and patient age. RESULTS: The highest accuracy was observed in medial meniscus and in ACL findings. For the medial meniscus sensitivity, specificity, agreement, and Kappa coefficient were 77, 92, 86%, and 0.7, and for the ACL these measures were 82, 97, 87%, and 0.73. MRI accuracy was lower in the lateral meniscus and articular cartilage with Kappa coefficient 0.42 and 0.3, respectively. More specifically, short peripheral tears in the posterior horn of the medial meniscus were characteristic of false negative findings compared to true positive findings of the MRI (p <  0.01). MRI accuracy correlated negatively compared to arthroscopic findings with patient age for the medial meniscus (r = - 0.21, p = 0.002) and for articular cartilage damage (r = - 0.45, p <  0.001). CONCLUSION: 1.5-Tesla MRI will accurately diagnose ACL and medial meniscal tears and can reliably complete the diagnostic workup following physical examination, particularly in young adults. This modality however is not reliable for diagnosing short peripheral tears at the posterior horn of the medial meniscus and partial thickness articular cartilage lesion of the femoral condyles. For these lesions, definitive diagnosis may require cartilage-specific MRI sequences or direct arthroscopic evaluation. LEVEL OF EVIDENCE: Prognostic study, Level III.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。