The effect of cochlear implant surgery on vestibular function in adults: A meta-analysis study

人工耳蜗植入手术对成人前庭功能的影响:一项荟萃分析研究

阅读:1

Abstract

ISSUE: The findings in literature indicate inconsistency in the complications caused by the implant of electrodes in the cochlea; vestibular alterations and balance disorders are mentioned as the most likely. PURPOSE: To evaluate, in literature, through the results of multiple vestibular function tests, the effects of cochlear implant surgery on postural stability in adult patients and to analyze. HYPOTHESIS: From the PICO strategy, where the Population focuses on adults, Intervention is cochlear implant surgery, Comparisons are between implanted patients, and Outcomes are the results of the assessment of cochlear function, the research question was formulated: Are there deficits in vestibular function in adults undergoing cochlear implant placement? METHOD: Systematic review based on cohort, case-control, and cross-sectional observational studies. Information sources: Databases between 1980 and 2021, namely, PubMed, Cinahl, Web Of Science, Cochrane, and Scopus. Search strategy using Mesh terms: "Adult," "Cochlear Implant," "Postural Balance," "Posturography," "Cochlear Implant," "Dizziness," "Vertigo," "Vestibular Functional Tests,"and "Caloric Tests." Populational inclusion criteria: studies with adult patients; intervention: cochlear implant placement surgery; comparison: analysis of a vestibular function with vestibular test results and pre- and postoperative symptoms; outcome: studies with at least one of the vestibular function tests, such as computerized vectoelectronystagmography (VENG), vestibular-evoked myogenic potentials (VEMPs), caloric test, video head impulse test (VHIT), head impulse test (HIT), videonystagmography, (VNG) and static and dynamic posturography. Exclusion criteria: studies without records of pre- and postoperative data collection and studies with populations under 18 years of age. Screening based on the reading of abstracts and titles was performed independently by two reviewers. In the end, with the intermediation of a third reviewer, manuscripts were included. Risk of bias analysis, performed by two other authors, occurred using the JBI "Critical Appraisal Checklist." RESULTS: Of the 757 studies, 38 articles met the inclusion criteria. VEMP was the most commonly used test by the studies (44.7%), followed by the caloric test (36.8%) and vHIT (23.6%). Most studies performed more than one test to assess vestibular function. CONCLUSION: Among all vestibular tests investigated, the deleterious effects on vestibular function after cochlear implant surgery were detected with statistical significance (P < 0.05) using VEMP and caloric test. Comparing abnormal and normal results after implant surgery, the vestibular apparatus was evaluated as having abnormal results after cochlear implant surgery only in the VEMP test. The other tests analyzed maintained a percentage mostly considered normal results. SYSTEMATIC REVIEW REGISTRATION: identifier: CRD42020198872.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。