Integrating O-RADS US v2022, CEUS, and CA125 to enhance the diagnostic differentiation of ovarian masses: development of the OCC-US model

整合 O-RADS US v2022、CEUS 和 CA125 以提高卵巢肿块的诊断鉴别能力:OCC-US 模型的开发

阅读:5

Abstract

PURPOSE: Differentiating between benign and malignant ovarian masses remains a significant clinical challenge. Although the Ovarian-Adnexal Reporting and Data System Ultrasound Version 2022 (O-RADS US v2022) provides standardized terminology and high sensitivity, its specificity remains suboptimal, potentially leading to overdiagnosis and overtreatment. Incorporating tumor vascularity evaluation via contrast-enhanced ultrasound (CEUS) and serum tumor markers like CA125 may enhance diagnostic accuracy and help guide clinical management more effectively. METHODS: A retrospective study of 909 patients with adnexal masses undergoing ultrasound at Sichuan Cancer Hospital from May 2022 to March 2025 was conducted. O-RADS US v2022, CEUS scores, and CA125 levels were analyzed to develop a novel scoring system (OCC-US). Diagnostic performance was evaluated using ROC curves, logistic regression, and inter-observer agreement analysis. Additionally, a temporally independent validation cohort was retrospectively assembled to assess the generalizability and diagnostic accuracy of the OCC-US model. RESULTS: A total of 609 patients were enrolled in the development cohort between May 2022 and May 2024. ROC analysis identified O-RADS US v2022 ≥ 4, CEUS score ≥ 4, and CA125 ≥ 37.815 U/mL as independent predictors of malignancy. Based on these variables, the OCC-US scoring system was developed, assigning 2 points each for O-RADS ≥ 4 and CEUS score ≥ 4, and 1 point for CA125 ≥ 37.815 U/mL (total score range: 0-5). OCC-US achieved the highest diagnostic performance with an AUC of 0.916, outperforming OC-US (0.891), CEUS (0.877), O-RADS US v2022 (0.871), and CA125 (0.784). It significantly improved specificity (85.4% vs. 71.5%, P < 0.001) while maintaining high sensitivity (84.9%), reducing the false-positive rate from 23.1% (O-RADS US v2022) to 6.2%. OCC-US also reduced unnecessary surgical recommendations from 300 (O-RADS US v2022) to 243 (P < 0.001). Inter-observer agreement was excellent (κ = 0.840, P < 0.001), indicating high reliability. In the temporally independent external validation cohort (300 patients enrolled between June 2024 and March 2025), the OCC-US model maintained stable diagnostic performance, with an AUC of 0.867. CONCLUSION: The OCC-US model enhances diagnostic specificity while maintaining high sensitivity, optimizing risk stratification and surgical decision-making. Further multi-center prospective studies are needed for broader validation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。