Verification of acromion marker cluster and scapula spinal marker cluster methods for tracking shoulder kinematics: a comparative study with upright four-dimensional computed tomography

验证肩峰标记簇和肩胛骨脊柱标记簇方法用于跟踪肩部运动学:与直立四维计算机断层扫描的比较研究

阅读:8
作者:Yuki Yoshida, Noboru Matsumura, Yoshitake Yamada, Azusa Miyamoto, Satoshi Oki, Minoru Yamada, Yoichi Yokoyama, Masaya Nakamura, Takeo Nagura, Masahiro Jinzaki

Background

This study validated the accuracy of the acromion marker cluster (AMC) and scapula spinal marker cluster (SSMC)

Conclusion

This study demonstrates that AMC is more accurate for assessing scapulothoracic upward rotation and glenohumeral elevation, while SSMC is preferable for evaluating scapulothoracic internal rotation, posterior tilting, glenohumeral external rotation, and anterior plane of elevation, with smaller differences compared to 4DCT.

Methods

Sixteen shoulders of eight healthy males underwent AMC and SSMC assessments. Active shoulder elevation was tracked using upright 4DCT and optical motion capture system. The scapulothoracic and glenohumeral rotation angles calculated from AMC and SSMC were compared with 4DCT. Additionally, the motion of these marker clusters on the skin with shoulder elevation was evaluated.

Results

The average differences between AMC and 4DCT during 10°-140° of humerothoracic elevation were - 2.2° ± 7.5° in scapulothoracic upward rotation, 14.0° ± 7.4° in internal rotation, 6.5° ± 7.5° in posterior tilting, 3.7° ± 8.1° in glenohumeral elevation, - 8.3° ± 10.7° in external rotation, and - 8.6° ± 8.9° in anterior plane of elevation. The difference between AMC and 4DCT was significant at 120° of humerothoracic elevation in scapulothoracic upward rotation, 50° in internal rotation, 90° in posterior tilting, 120° in glenohumeral elevation, 100° in external rotation, and 100° in anterior plane of elevation. However, the average differences between SSMC and 4DCT were - 7.5 ± 7.7° in scapulothoracic upward rotation, 2.0° ± 7.0° in internal rotation, 2.3° ± 7.2° in posterior tilting, 8.8° ± 7.9° in glenohumeral elevation, 2.0° ± 9.1° in external rotation, and 1.9° ± 10.1° in anterior plane of elevation. The difference between SSMC and 4DCT was significant at 50° of humerothoracic elevation in scapulothoracic upward rotation and 60° in glenohumeral elevation, with no significant differences observed in other rotations. Skin motion was significantly smaller in AMC (28.7 ± 4.0 mm) than SSMC (38.6 ± 5.8 mm). Although there was smaller skin motion in AMC, SSMC exhibited smaller differences in scapulothoracic internal rotation, posterior tilting, glenohumeral external rotation, and anterior plane of elevation compared to 4DCT.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。